Mitsubishi Electronics C6/C64 Life Jacket User Manual


 
APPENDIX 7 CABLE MANUFACTURING DRAWINGS
Appendix 7.15 FCUA-R220 Cable Manufacturing Drawing
I - 100
Appendix 7.15 FCUA-R220 Cable Manufacturing Drawing
Application:
Supply of 24V to control unit,
remote I/O unit and communication terminal
Option (Compatible connector set)
FCUA-CN220
(Note that this corresponds only to the
connector on the control unit side.)
List of parts used
1 2
3
4
FG
GND
+24V
R220
Note (3)
Y
R220
Assembly drawing
No.
Part
name/model
Maker Q'ty
1
Connector
2-178288-3
Tyco
Electronics
AMP
1
2
Contact
1-175218-5
Tyco
Electronics
AMP
3
3
Wire material
JPVV-SB
1P × 0.5mm
2
BANDO
Electric
Industry
Note (1)
(1)
4
Crimp terminal
V1.25-3
J. S. T 3
WHITE
BROWN
Maximum cable length: 30m
FG
GND
+24V
3
2
1
FG
GND
+24V
Connection diagram
Manufacturing precautions
(1) The wire material shall be a shielded 1-pair stranded cable equivalent to AWG20 (0.5mm
2
).
If the cable is 10m or longer, select AWG16 (1.25mm
2
) material or equivalent.
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(3) Attach the nameplate (with protective cover stamped with the cable name) in the position
designated in the assembly drawing.
(4) Install each crimp terminal side after stamping the name of each signal on the mark tube.
(5) Protect both ends of the wire material with insulation bushing.
(6) Use AWG18 (0.75mm
2
) or equivalent for the shield treatment wire material.