APPENDIX 7 CABLE MANUFACTURING DRAWINGS
Appendix 7.2 F311 Cable Manufacturing Drawing
I - 87
Appendix 7.2 F311 Cable Manufacturing Drawing
Application : Control unit - serial device connection
(Cable from control unit to junction plate.)
List of parts used
Control unit side
1
2
3
7
7
4
5
6
4
5
6
F311A
F311A
Note (3)
RS232 GPP
Note (4)
SIO
Junction plate side
A
ssembly drawing
No. Part name/type Maker Q’ty
1
Connector
10120-6000VE
Sumitomo 3M 1
2
Connector case
10320-3210-000
Sumitomo 3M 1
3
Wire material
UL20276
AWG28
× 10P
Note (1) (1)
4
Connector
CDB-25S
Hirose Electric 2
5
Contact
CD-SC-111
Hirose Electric 21
6
Lock nut
HD-LNA
Hirose Electric 4
7
F installation
plate
N750D714H01
Mitsubishi Electric
(Refer to dimen-
sion drawing)
2
Maximum cable length: 8m
(Note 5)
RS-232C
Control unit side
SIO
2
12
3
13
4
14
1
3
2
5
4
6
20
7
Case GND plate
RS-422
(
GPP
)
11
5
15
10
20
7
17
8
18
6
16
9
19
20
7
8
21
12
13
3
16
2
15
5
18
4
17
RXD
TXD
CTS
RTS
DSR
DTR
SG
SG
SG
SG
SG
(
SEL
)
+5V
+5V
TXD
TXD*
RXD
RXD*
DTR
DTR*
DCD
DCD*
Connection diagram
(5.5)
5.5
65
47.1
±
0.2
42.6
±
0.2
2-R2.5
2-R1.75
5
38
76
6
±
0.1
12
24
Plate thickness: 1.6mm
F installation plate outline dimensions drawing
Manufacturing precautions
(1) The wire material shall be a shielded, 10-pair stranded cable equivalent to UL20276 Standards
AWG28 (0.08mm
2
).
(2) The parts used shall be Mitsubishi recommended parts. Equivalent parts may be used providing
they are compatible with the specifications.
(3) Attach the nameplate (with protective cover stamped with the cable name) in the position
designated in the assembly drawing. The Mitsubishi-supplied cable is labeled “F311A” due to a
change of its connection.
(4) Provide a protective cover from the exposed part of the branching section wire to the connector,
and fix with a bundling band.
(5) The total length of the cable, including the length from this cable to the cable connected to the
RS-232C device, must be 15m or less.