Mitsubishi Electronics C6/C64 Life Jacket User Manual


 
5. CONNECTION OF COMMUNICATION TERMINAL
5.2 Connection of Power Supply
I
- 49
5.2 Connection of Power Supply
The 24VDC must be supplied to the communication terminal.
Prepare a stabilized power supply that satisfies the following conditions.
The 9-type CRT type requires 100VAC for the CRT power supply.
Type
FCUA-LD100/
LD10
FCU6-DUT32
FCUA-CT100/
CT120/KB10
Power voltage
24VDC±5%
Ripple ±5% (p-p)
Instantaneous power failure
tolerable time
Follows specifications of 24VDC power supply being used
Current consumption 24VDC, 0.9A 24VDC, 0.9A 24VDC, 0.6A
5.2.1 Connection of Power Supply to 7.2-type Monochrome LCD
(FCUA-LD100/FCUA-LD10+KB20)
Supply 24VDC to the CR01 connector on the rear of the LCD.
LCD
J1
J2
CR03
CR02
CR05
CR06
CNZ24
CR01
[FCUA-LD100/LD10+KB20 rear side]
FG 3
0V 2
24VDC(+) 1
R220 cable
24VDC(+)
0V
FG
Stabilized
power supply
FG
Y
CAUTION
Separate the signal wire from the drive line/power line when wiring.
Do not apply voltages other than those indicated in this manual on the connector. Doing
so may lead to destruction or damage.
Incorrect connections may damage the devices, so connect the cables to the specified
connectors.
Recommended adaptive connector
(Enclosed with FCUA-LD100/FCUA-LD10+KB20)
Connector : 2-178288-3
Contact : 1-175218-5 (tin plated) (Tyco Electronics AMP)