Mitsubishi Electronics C6/C64 Life Jacket User Manual


 
6. CONNECTION OF REMOTE I/O UNIT
6.11 Connection of FCUA-DX12 Unit and Machine Control Signal
I
- 69
<Signal assignment table>
<CAUTION>
When using two or more remote I/O units or when
connecting to the communication terminal, the signal
assignment will differ.
Refer to the "PLC interface manual" for details.
24VDC(+)
0V
RA
24VDC(+)
0V
PL
0V
24VDC(+)
FCUA-DX12
Y
DCIN
1 2 3
+24V 0V FG
RIO1
1 2 3
TxRx TxRx* LG
RIO2
1 2 3
TxRx TxRx* LG
X
X
24VDC(+)
0V
RA
24VDC(+)
0V
PL
DI-L
DI-R
DO-L
DO-R
B
X20
X21
X22
X23
X24
X25
X26
X27
X28
X29
X2A
X2B
X2C
X2D
X2E
X2F
COM
+24V
+24V
B
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
A
X30
X31
X32
X33
X34
X35
X36
X37
X38
X39
X3A
X3B
X3C
X3D
X3E
X3F
COM
0V
0V
A
DI-R
B
Y20
Y21
Y22
Y23
Y24
Y25
Y26
Y27
Y28
Y29
Y2A
Y2B
Y2C
Y2D
Y2E
Y2F
A
O
+24V
+24V
B
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
A
A
O*
0V
0V
A
DO-R
B
Y00
Y01
Y02
Y03
Y04
Y05
Y06
Y07
Y08
Y09
Y0A
Y0B
Y0C
Y0D
Y0E
Y0F
+24V
+24V
B
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
A
Y10
Y11
Y12
Y13
Y14
Y15
Y16
Y17
Y18
Y19
Y1A
Y1B
Y1C
Y1D
Y1E
Y1F
0V
0V
A
DO-L
DI-L
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
A
X10
X11
X12
X13
X14
X15
X16
X17
X18
X19
X1A
X1B
X1C
X1D
X1E
X1F
COM
0V
0V
A
B
X00
X01
X02
X03
X04
X05
X06
X07
X08
X09
X0A
X0B
X0C
X0D
X0E
X0F
COM
+24V
+24V
B
Control unit
Communication
Terminal
R-TM
Remote I/O unit
Machine side
control panel, etc.
<Adaptive connector>
X
Y
Terminator (R-TM)
Maker: Tyco Electronics AMP
X
DI-L/DO-L (CN300)
DI-R/DO-R
Crimp type : 7940-6500SC
connector
Maker : Sumitomo 3M
RIO1/RIO2 (CN211)
Connector : 1-178288-3
Contact : 1-175218-2
Maker : Tyco
Electronics AMP
DCIN (CN220)
Connector : 2-178288-3
Contact : 1-175218-5
Maker : Tyco
Electronics AMP