Mitsubishi Electronics FR-D720S-008 Marine Battery User Manual


 
244
Check and clear of the faults history
4.25 Check and clear of the faults history
(1) Check for the faults history
Faults history
Monitor/frequency setting
[Operation panel is
used for operation]
Parameter setting
[Parameter setting change]
[Operation for displaying the faults history]
Past eight faults can be displayed with the setting dial.
(The latest fault is ended by ".".)
When no fault exists, i is displayed.
Flickering
Output frequency
Output current
Flickering
Flickering
Flickering
Flickering
Press the
setting dial.
Press the
setting dial.
Press the
setting dial.
Faults history number
(The number of past faults is displayed.)
Hz
A
Output voltage
Flickering
Energization time
Flickering