Mitsubishi Electronics FR-D720S-008 Marine Battery User Manual


 
92
Frequency setting by external terminals
(2) Jog operation from PU
Selects Jog operation mode from the operation panel and PU (FR-PU04/FR-PU07). Operation is performed only while the
start button is pressed.
Operation Display
1. Confirmation of the RUN indication and
operation mode indication
The monitor mode should have been
selected.
The inverter should be at a stop.
2. Press to choose the PU Jog operation
mode.
3. Press .
While is pressed, the motor rotates.
The motor runs at 5Hz. (Pr. 15 initial value)
Press
4. Release
Release
[When changing the frequency of PU Jog operation]
5. Press to choose the parameter setting
mode.
PRM indication is lit.
(The parameter number read previously
appears.)
6. Turn until Pr. 15 Jog frequency appears.
7. Press to show the present set value.
(5Hz)
8. Turn to set the value to " ".
(10Hz)
9. Press to set.
Flicker...Parameter setting complete!!
10.Perform the operations in steps 1 to 4.
The motor rotates at 10Hz.
Three-phase AC
power supply
Inverter
R/L1
S/L2
T/L3
U
V
W
Operation panel
Motor
Stop