Mitsubishi Electronics FR-D720S-008 Marine Battery User Manual


 
Parameter listParameter list
60
4
PARAMETERS
Parameter List
Motor constants
80 Motor capacity 0.1 to 7.5kW, 9999 0.01kW 9999 75, 105 80 50 D0 0 ×
82 Motor excitation current 0 to 500A, 9999
0.01A 9999 105 82 52 D2 0 × ×
83 Rated motor voltage 0 to 1000V 0.1V
200V/400V
∗5
105 83 53 D3 0 ×
84 Rated motor frequency 10 to 120Hz 0.01Hz 60Hz 105 84 54 D4 0 × 
90 Motor constant (R1) 0 to 50 , 9999 0.001 9999 105 90 5A DA 0 ×
96 Auto tuning setting/status 0, 11, 21 1 0
105,
136
96 60 E0 0 ×
PU connector communication
117 PU communication station number 0 to 31 (0 to 247) 1 0
183,
200
117 11 91 1 ∗7 ∗7
118 PU communication speed 48, 96, 192, 384 1 192
183,
200
118 12 92 1  ∗7 ∗7
119 PU communication stop bit length 0, 1, 10, 11 1 1 183 119 13 93 1 ∗7 ∗7
120 PU communication parity check 0, 1, 2 1 2
183,
200
120 14 94 1  ∗7 ∗7
121 Number of PU communication retries 0 to 10, 9999 1 1 184 121 15 95 1 ∗7 ∗7
122 PU communication check time interval 0, 0.1 to 999.8s, 9999 0.1s 0
184,
200
122 16 96 1  ∗7 ∗7
123 PU communication waiting time setting 0 to 150ms, 9999 1 9999 183 123 17 97 1 ∗7 ∗7
124 PU communication CR/LF selection 0, 1, 2 1 1 183 124 18 98 1  ∗7 ∗7
125
Terminal 2 frequency setting gain
frequency
0 to 400Hz 0.01Hz 60Hz 153 125 19 99 1 ×
126
Terminal 4 frequency setting gain
frequency
0 to 400Hz 0.01Hz 60Hz 153 126 1A 9A 1 ×
PID operation
127
PID control automatic switchover
frequency
0 to 400Hz, 9999 0.01Hz 9999 212 127 1B 9B 1
128 PID action selection 0, 20, 21, 40 to 43 1 0
212,
220
128 1C 9C 1 
129 PID proportional band 0.1 to 1000%, 9999 0.1% 100%
212,
220
129 1D 9D 1
130 PID integral time 0.1 to 3600s, 9999 0.1s 1s
212,
220
130 1E 9E 1 
131 PID upper limit 0 to 100%, 9999 0.1% 9999
212,
220
131 1F 9F 1
132 PID lower limit 0 to 100%, 9999 0.1% 9999
212,
220
132 20 A0 1 
133 PID action set point 0 to 100%, 9999 0.01% 9999
212,
220
133 21 A1 1
134 PID differential time 0.01 to 10s, 9999 0.01s 9999
212,
220
134 22 A2 1 
PU
145 PU display language selection 0 to 7 1 1 237 145 2D AD 1 × ×
146 Parameter for manufacturer setting. Do not set. 146 Parameter for manufacturer setting. Do not set.
Current
detection
150 Output current detection level 0 to 200% 0.1% 150% 124 150 32 B2 1
151
Output current detection signal delay
time
0 to 10s 0.1s 0s 124 151 33 B3 1 
152 Zero current detection level 0 to 200% 0.1% 5% 124 152 34 B4 1
153 Zero current detection time 0 to 1s 0.01s 0.5s 124 153 35 B5 1 
156 Stall prevention operation selection 0 to 31, 100, 101 1 0 79 156 38 B8 1
157 OL signal output timer 0 to 25s, 9999 0.1s 0s 79 157 39 B9 1 
158 AM terminal function selection
1 to 3, 5, 8 to 12, 14, 21,
24, 52, 53, 61, 62
1 1 128 158 3A BA 1
160 Extended function display selection 0, 9999 1 0 162 160 00 80 2 
161
Frequency setting/key lock operation
selection
0, 1, 10, 11 1 0 238 161 01 81 2 ×
Automatic restart
functions
162
Automatic restart after instantaneous
power failure selection
0, 1, 10, 11 1 1 136 162 02 82 2 
165
Stall prevention operation level for
restart
0 to 200% 0.1% 150% 136 165 05 85 2
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Remarks
Instruction Code
Control Mode-based
Correspondence Table
Parameter
Read Write
Extended
Copy Clear
All clear
V/F
V/F
V/F
GP
MFVC
GP
MFVC
GP
MFVC