564 Operating time carrying-over times (0 to 65535) 1 0 128 564 40 C0 5 × × ×
571 Holding time at a start 0 to 10s, 9999 0.1s 9999 98 571 47 C7 5 
PID
operation
575 Output interruption detection time 0 to 3600s, 9999 0.1s 1s 212 575 4B CB 5
576 Output interruption detection level 0 to 400Hz 0.01Hz 0Hz 212 576 4C CC 5 
577 Output interruption cancel level 900 to 1100% 0.1% 1000% 212 577 4D CD 5
611 Acceleration time at a restart 0 to 3600s, 9999 0.1s 9999 136 611 0B 8B 6 
653 Speed smoothing control 0 to 200% 0.1% 0 149 653 35 B5 6
665
Regeneration avoidance frequency
gain
0 to 200% 0.1% 100 226 665 41 C1 6 
Protective
functions
872 ∗8 Input phase loss protection selection 0, 1 1 0 146 872 48 C8 8
Regeneration avoidance
function
882
Regeneration avoidance operation
selection
0, 1, 2 1 0 226 882 52 D2 8 
883
Regeneration avoidance operation
level
300 to 800V 0.1V
400VDC/
780VDC
∗5
226 883 53 D3 8
885
Regeneration avoidance compensation
frequency limit value
0 to 10Hz, 9999 0.01Hz 6Hz 226 885 55 D5 8 
886 Regeneration avoidance voltage gain 0 to 200% 0.1% 100% 226 886 56 D6 8
Free
parameter
888 Free parameter 1 0 to 9999 1 9999 236 888 58 D8 8 ××
889 Free parameter 2 0 to 9999 1 9999 236 889 59 D9 8 × ×
891
Cumulative power monitor digit shifted
times
0 to 4, 9999 1 9999 128 891 5B D8 8 
Calibration parameters
C1
(901)
∗6
AM terminal calibration 134
C1
(901)
5D DD 1 ×
C2
(902)
∗6
Terminal 2 frequency setting bias
frequency
0 to 400Hz 0.01Hz 0Hz 153
C2
(902)
5E DE 1 ×
C3
(902)
∗6
Terminal 2 frequency setting bias 0 to 300% 0.1% 0% 153
C3
(902)
5E DE 1 ×
125
(903)
∗6
Terminal 2 frequency setting gain
frequency
0 to 400Hz 0.01Hz 60Hz 153
125
(903)
5F DF 1 ×
C4
(903)
∗6
Terminal 2 frequency setting gain 0 to 300% 0.1% 100% 153
C4
(903)
5F DF 1 ×
C5
(904)
∗6
Terminal 4 frequency setting bias
frequency
0 to 400Hz 0.01Hz 0Hz 153
C5
(904)
60 E0 1 ×
C6
(904)
∗6
Terminal 4 frequency setting bias 0 to 300% 0.1% 20% 153
C6
(904)
60 E0 1 ×
126
(905)
∗6
Terminal 4 frequency setting gain
frequency
0 to 400Hz 0.01Hz 60Hz 153
126
(905)
61 E1 1 ×
C7
(905)
∗6
Terminal 4 frequency setting gain 0 to 300% 0.1% 100% 153
C7
(905)
61 E1 1 ×
C22 to C25
(922 to 923)
Parameter for manufacturer setting. Do not set.
C22 to C25
(922 to 923)
Parameter for manufacturer setting. Do not set.
PU
990 PU buzzer control 0, 1 1 1 241 990 5A DA 9
991 PU contrast adjustment 0 to 63 1 58 241 991 5B DB 9 ×
Func-
tion
Parameter
Name Setting Range
Minimum
Setting
Increments
Initial
Value
Refer
to
Page
Customer
Setting
Parameter
Remarks
Instruction Code
Control Mode-based
Correspondence Table
Parameter
Read Write
Extended
Copy Clear
All clear
V/F
V/F
V/F
GP
MFVC
GP
MFVC
GP
MFVC