ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 108 November 2003 © TOSHIBA TEC
568
569
570
571
572
573
574
575
576
583-0
583-1
583-2
Image
control
Image
control
Image
control
Image
control
Image
control
Image
control
Image
control
Image
control
Image
control
Fuser
Image quality closed-loop
control automatic start-up/
When recovered from “Toner
empty”
Image quality closed-loop
control automatic start-up/
Temperature setting of fuser
roller at power-ON
Image quality closed-loop
control automatic start-up/
Relative humidity difference
setting
Image quality closed-loop
control automatic start-up/
Setting of period of time
unattended
Image quality closed-loop
control automatic start-up/
Setting of accumulated print
volume
Abnormality detection count
(Y)
Display/0 clearing
Abnormality detection count
(M)
Display/0 clearing
Abnormality detection count
(C)
Display/0 clearing
Abnormality detection count
(K)
Display/0 clearing
Pre-running time
at power-ON and
ready status
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
ALL
ALL
ALL
ALL
ALL
ALL
2
<0-2>
8
<0-20>
4
<0-6>
4
<0-24>
10
<0-30>
0
<0-16>
0
<0-16>
0
<0-16>
0
<0-16>
1
<0-10>
4
<0-10>
7
<0-10>
M
M
M
M
M
M
M
M
M
M
M
M
Sets whether or not performing
closed-loop control automatically
when recovered from “Toner empty”.
0: Invalid 1: Valid (at mode 1)
2: Valid (at mode 2)
Sets the fuser roller temperature to
perform closed-loop control when “1”
or “2” (valid) is set in 08-559.
0: 20°C 1: 25°C 2: 30°C
3: 35°C 4: 40°C 5: 45°C
6: 50°C 7: 55°C 8: 60°C
9: 65°C 10: 70°C 11: 75°C
12: 80°C 13: 85°C 14: 90°C
15: 95°C 16: 100°C 17: 105°C
18: 110°C 19: 115°C 20: 120°C
Sets the relative humidity difference
to perform the closed-loop control
when “1” or “2” (valid) is set in 08-
565.
0: 0% 1: 5% 2: 10% 3: 15%
4: 20% 5: 25% 6: 30%
Sets the period of time unattended to
perform closed-loop control when “1”
or “2” (valid) is set in 08-566.
Setting value x 1 (hour)
Sets the number of accumulated print
volume to perform closed-loop
control when “1” or “2” (valid) is set in
08-567.
Setting value x 100 (pages)
Counts the abnormality detection of
image quality control. Accumulating
total of [CE10], [CE20] and [CE40]
Counts the abnormality detection of
image quality control. Accumulating
total of [CE10], [CE20] and [CE40]
Counts the abnormality detection of
image quality control. Accumulating
total of [CE10], [CE20] and [CE40]
Counts the abnormality detection of
image quality control. Accumulating
total of [CE10], [CE20] and [CE40]
0: 3 sec. 1: 6 sec. 2: 9 sec.
3: 12 sec. 4: 15 sec. 5: 18 sec.
6: 21 sec. 7: 24 sec. 8: 27 sec.
9: 30 sec. 10: 33 sec.
1
1
1
1
1
1
1
1
1
4
4
4
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Acceptable
value>
RAM Contents
Proce-
dure
Transport
motor
speed 1/1
Transport
motor
speed 1/2
Transport
motor
speed 1/3