Toshiba 4511 Marine Radio User Manual


 
November 2003 © TOSHIBA TEC 2 - 27 e-STUDIO3511/4511
ERROR CODE AND SELF-DIAGNOSTIC MODE
A—
B—
C—
[6]
D APS sensor (APS-R) No original
E APS sensor (APS-C) No original
F APS sensor (APS-3) No original
G APS sensor (APS-2) No original
H APS sensor (APS-1) No original
A RADF tray sensor Original present
B RADF empty sensor Original present
C RADF jam access cover switch Cover opened
[7]
D RADF open/close sensor RADF opened
E RADF exit sensor Original present
F RADF reverse sensor Original present
G RADF read sensor Original present
H RADF registration sensor Original present
A—
B—
C—
[8]
D—
E RADF original length sensor Original present
F RADF original width sensor 1 Original present
G RADF original width sensor 2 Original present
H RADF original width sensor 3 Original present
A Black toner cartridge switch Cartridge not installed
B—
C—
[9]
D Bypass feed sensor No paper
E Registration sensor Paper present
F—
G—
H Transfer belt home position sensor Home position
A Bridge unit transport sensor 2 Paper present
B Bridge unit cover open/close detection switch Cover opened
C Bridge unit transport sensor 1 Paper present
[0]
D Bridge unit paper full detection sensor Paper not full
E—
F Charger cleaner front position detection switch Cleaner home position
G Charger cleaner rear position detection switch Cleaner rear position
H—
Digital
Button
Items to check
Condition
key with highlighted button
[FAX] button: OFF/[COPY] button: ON ([FAX] LED: OFF/[COPY] LED: ON)
Items to check
Temperature/humidity sensor
Temperature/humidity sensor
Drum thermistor
Display on the touch panel
Displays the temperature inside the equipment. (Unit: °C)
Displays the humidity inside the equipment. (Unit: %RH)
Displays the temperature near the drum surface. (Unit: °C)
Digital
key
[1]
[2]
[3]