Toshiba 4511 Marine Radio User Manual


 
November 2003 © TOSHIBA TEC 4 - 3 e-STUDIO3511/4511 PREVENTIVE MAINTENANCE
1
23 45 6
9
78
(b) Sub screen
Fig. 4-103
Displaying of the sub unit (parts) name
Back to the main screen
Clearing of the chosen sub unit (parts) counters
Moving to the next/previous page
Displaying of the present number of output pages / develop counts (x1,000)
” is displayed next to the present number when the number of output pages or develop
counts has exceeded its PM standard number.
Displaying of the standard number of output pages / develop counts (x1,000) to replace the
sub unit (parts)
Displaying of the present drive counts (x1,000)
” is displayed next to the present number when the number of drive counts has exceeded
its PM standard number.
Displaying of the standard number of drive counts (x1,000) to replace the sub unit (parts)
Displaying of the number of output pages, develop counts and drive counts and previous
replacement date for a chosen sub unit