November 2003 © TOSHIBA TEC 3 - 91 e-STUDIO3511/4511 ADJUSTMENT
3.16 Adjustment of Transfer Belt Deviation
3.16.1 Outline
If any transfer belt deviation (See 3.16.2) occurs when the equipment is installed, moved to another
place or the transfer belt is replaced, perform this adjustment.
3.16.2 Transfer belt deviation
Transfer belt deviation means that the transfer belt is not in the following normal condition. Check the
equipment and if the transfer belt does not conform to the conditions described below, perform the
adjustment according to the adjustment procedure of 3.16.3.
(1) Open the 2nd transfer unit and check the gaps between both ends of the transfer belt and the
regulation plates. They should be 0.2 mm or more.
(2) The gaps remain the same after the transfer belt has been rotated for 3 minutes or more. (The
belt should not be dislocated to the front or rear side.)
Fig. 3-1601
05/03
0.2mm or more
0.2mm or more