Toshiba 4511 Marine Radio User Manual


 
e-STUDIO3511/4511
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 116 November 2003 © TOSHIBA TEC
Remote-controlled service
function
Remote-controlled service
HTTP server
URL setting
Remote-controlled service
HTTP initially-registered
server
URL setting
Short time interval setting of
recovery from Emergency
Mode
Short time interval setting of
Emergency Mode
Remote-controlled service
periodical polling timing
(Hour/Hour/Minute/Minute)
Remote-controlled service
Writing data of self-
diagnostic code
Remote-controlled service
response waiting time
(Timeout)
Remote-controlled service
initial registration
Remote-controlled service
tentative password
Status of remote-controlled
service initial registration
(Display only)
Service center call function
Service center call
HTTP server URL setting
HTTP proxy setting
HTTP proxy IP address
setting
HTTP proxy port number
setting
HTTP proxy ID setting
HTTP proxy password
setting
HTTP proxy panel display
Automatic ordering function
of supplies
702
703
707
710
711
715
716
717
718
719
720
721
723
726
727
728
729
730
731
732
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
Mainte-
nance
(Remote)
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
2
<0-2>
-
https://
device.mfp-
support.com:
443/device/
firstregist.ashx
24
<1-48>
60
<30-360>
1230
0
<0-1>
3
<1-30>
0
<0-1>
-
0
<0-1>
2
<0-2>
-
1
<0-1>
-
0
<0-65535>
-
-
1
<0-1>
3
<0-3>
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
SYS
0: Valid (Remote-controlled server)
1: Valid (L2) 2: Invalid
Maximum 256 Bytes
Maximum 256 Bytes
Sets the time interval to recover from
the Emergency Mode to the Normal
Mode.
(Unit: Hour)
Unit: Minute
0 (0:00) to 2359 (23:59)
0: Prohibited 1: Accepted
Unit: Minute
0: OFF 1: Start
2: Only certification is scanned
Maximum 10 letters
0: Not registered
1: Registered
0: OFF
1: Notifies all service calls
2: Notifies all but paper jams
Maximum 256 letters
0: Valid 1: Invalid
000.000.000.000 - 255.255.255.255
(Default value 000.000.000.000)
Maximum 30 letters
Maximum 30 letters
0: Valid 1: Invalid
0: Ordered by FAX
1: Ordered by E-mail
2: Ordered by HTTP
3: OFF
1
11
11
1
1
1
1
1
1
11
2
1
11
1
11
1
11
11
1
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Acceptable
value>
RAM Contents
Proce-
dure
05/05