Toshiba 4511 Marine Radio User Manual


 
e-STUDIO3511/4511
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 122 November 2003 © TOSHIBA TEC
Color auto-toner sensor/
sensor OFF output value
display at power ON
Color auto-toner sensor/
reference plate output value
display at power ON
Color auto-toner
sensor/abnormal
detection potential
difference setting
of reference plate
output
Color auto-toner control
environment and life light
amount correction setting
Color auto-toner adjustment
finishing range setting
Color auto-toner control
environment and life light
amount correction/correction
finishing range setting
Color auto-toner sensor/
setting of number of times of
error detection at light
amount correction
Color auto-toner control
environment and life light
amount correction/display of
number of times of reference
plate detection error
Color auto-toner control
environment and life light
amount correction/display of
number of times of light
amount control voltage
adjustment error
Color auto-toner
control/developer
initial output
setting
Develop-
ment
Develop-
ment
Develop-
ment
Develop-
ment
Develop-
ment
Develop-
ment
Develop-
ment
Develop-
ment
Develop-
ment
Develop-
ment
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
-
<0-1023>
-
<0-1023>
820
<0-1023>
205
<0-1023>
0
<0-1>
4
<0-255>
5
<0-255>
3
<0-255>
0
<0-255>
0
<0-255>
256
<0-1023>
256
<0-1023>
256
<0-1023>
M
M
M
M
M
M
M
M
M
M
M
M
M
Displays the sensor output value
when the sensor light source is OFF
at power ON.
Displays the sensor output value with
the standard light amount for the
reference plate at power ON.
Sets the range for judging whether
the difference between the sensor
output when the sensor light source
is OFF and the sensor output for the
reference plate is correct or not.
Sets whether the sensor light amount
is corrected or not depending on the
environment and life.
0: Correction 1: No correction
Sets the difference from the target
value for judging whether the color
auto-toner adjustment finishes
correctly or not.
Sets the difference from the target
value for judging whether the light
amount correction finishes correctly
or not.
Sets the number of times of
continuous error detection before the
light amount correction abnormality is
displayed.
Displays the number of times of the
reference plate detection error for the
environment and life light amount
correction.
Displays the number of times of the
light amount control voltage
adjustment error for the environment
and life light amount correction.
Sets the initial developer output
target value.
Upper
limit
Lower
limit
Y
M
C
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Acceptable
value>
RAM Contents
Proce-
dure
864
865
866-0
866-1
867
868
869
870
871
872
873-0
873-1
873-2
2
2
4
4
1
1
1
1
2
2
4
4
4