November 2003 © TOSHIBA TEC 2 - 153 e-STUDIO3511/4511
ERROR CODE AND SELF-DIAGNOSTIC MODE
<<Procedure to copy the total counter value (08-257)>>
1. Turn ON the power while [0] and [8] are pressed simultaneously.
2. Key in the code “257” and press the [START] button (the following is displayed).
Note:
Before performing the following operations, note the current counter values.
3. Key in the value “1” or “2” and press the [START] button.
The value entered is displayed on the left of the “%”, and the [ENTER] button is displayed.
Note:
The value can be erased by pressing the [CLEAR] button to change as long as the [START]
button is not pressed. (The value on the left of the “%” is reset to “0” by pressing the [CLEAR]
button.)
• Key in “1” to copy the value of the total
counter (LGC board) (A) onto the value of
the backup counter (SYS board) (B).
• Key in “2” to copy the value of the backup
counter (SYS board) (B) onto the value of
the total counter (LGC board) (A).
4. Press the [ENTER] button to complete
overwriting of the counter value.
Note:
The screen returns to the code entry screen
without copying (overwriting) the value when
the [CANCEL] button is pressed.
(A)
(B)
(A)
(B)
04/09