Toshiba 4511 Marine Radio User Manual


 
November 2003 © TOSHIBA TEC 2 - 121 e-STUDIO3511/4511
ERROR CODE AND SELF-DIAGNOSTIC MODE
Develop-
ment
Develop-
ment
Fuser
Develop-
ment
Develop-
ment
Develop-
ment
Develop-
ment
Develop-
ment
Develop-
ment
823-0
823-1
823-2
824-0
824-1
824-2
849
858-0
858-1
858-2
859-0
859-1
859-2
860-0
860-1
861-0
861-1
862-0
862-1
863-0
863-1
Color auto-toner
sensor/light
amount correction
voltage abnormal
detection
Color auto-toner
sensor/toner
density detection
voltage abnormal
detection
Fusing control switching for
TWD and SAD models
Toner empty
detection
Color toner forced
supply level
display
Color auto-toner
sensor/proper
range setting of
OFF level voltage
Color auto-toner
sensor/proper
range setting of
standard light
amount voltage
Color auto-toner
sensor/proper
range setting of
reference plate
output
Color auto-toner
sensor/proper
range setting of
developer output
0
<0-1>
0
<0-1>
0
<0-1>
0
<0-1>
0
<0-1>
0
<0-1>
Other than
TWD and
SAD: 0
TWD and
SAD: 1
<0-1>
0
<0-1>
0
<0-1>
0
<0-1>
0
<0-1>
0
<0-1>
0
<0-1>
20
<0-1023>
0
<0-1023>
205
<0-255>
40
<0-255>
820
<0-1023>
205
<0-1023>
450
<0-1023>
155
<0-1023>
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
ALL
(color)
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
Displays “1” when the abnormal
output voltage is detected for the
color auto-toner sensor light amount
correction. ([CF40] error)
0: Normal
1: Abnormality detected
Displays “1” when the abnormal
toner density detection voltage is
detected. ([CF20] error)
0: Normal
1: Abnormality detected
Becomes “1” when detecting the
toner empty.
0: Normal
1: Empty detected
Becomes “1” when the toner density
decreases and it is judged forced
toner supply is needed.
0: Normal level
1: Forced supply level
Sets the range for judging whether
the sensor output value when the
sensor light source is OFF is correct
or not.
Sets the range for judging whether
the adjustment result of sensor light
amount is correct or not.
Sets the range for judging whether
the sensor output value for the
reference plate is correct or not.
Sets the range for judging whether
the sensor output value for the
sleeve is correct or not.
4
4
4
4
4
4
1
14
14
14
14
14
14
4
4
4
4
4
4
4
4
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Acceptable
value>
RAM Contents
Proce-
dure
Y
M
C
Y
M
C
Y
M
C
Y
M
C
Upper
limit
Lower
limit
Upper
limit
Lower
limit
Upper
limit
Lower
limit
Upper
limit
Lower
limit
04/05