Mitsubishi Electronics FR-A701 Marine Battery User Manual


 
100
Parameter List
4.6 Parameter List
4.6.1 List of parameters classified by the purpose
This Instruction Manual provides basic explanation of parameters. For parameters not stated, refer to the Chapter 4
Parameter of the Instruction Manual (Applied).
Set the parameters according to the operating conditions. The following list indicates purpose of use and
corresponding parameters.
Purpose of Use Parameter Number
Control mode Change the control method Pr. 80, Pr. 81, Pr. 451, Pr. 800
Speed control by Real
sensorless vector control and
vector control
Torque limit level setting for speed control
Pr. 22, Pr. 803, Pr. 810 to Pr. 817,
Pr. 858, Pr. 868, Pr. 874
To perform high accuracy/fast response operation (gain
adjustment of Real sensorless vector control and vector
control)
Pr. 818 to Pr. 821, Pr. 830, Pr. 831,
Pr. 880
Speed feed forward control, model adaptive speed control Pr. 828, Pr. 877 to Pr. 881
Torque bias function Pr. 840 to Pr. 848
Prevent the motor from overrunning Pr. 285, Pr. 853, Pr. 873
Notch filter Pr. 862, Pr. 863
Torque control by Real
sensorless vector control and
vector control
Torque command Pr. 803 to Pr. 806
Speed limit Pr. 807 to Pr.809
Gain adjustment for torque control Pr. 824, Pr. 825, Pr. 834, Pr. 835
Position control by vector
control
Simple position feed function by contact input Pr. 419, Pr. 464 to Pr. 494
Position control by pulse train input of the inverter Pr. 419, Pr. 428 to Pr. 430
Setting the electronic gear Pr. 420, Pr. 421, Pr. 424
Setting of positioning adjustment parameter Pr. 426, Pr. 427
Gain adjustment of position control Pr. 422, Pr. 423, Pr. 425
Adjust the output torque of
the motor (current)
Manual torque boost Pr. 0, Pr. 46, Pr. 112
Advanced magnetic flux vector control
Pr. 80, Pr. 81, Pr. 89, Pr. 453, Pr. 454,
Pr. 569
Real sensorless vector control Pr. 80, Pr. 81, Pr. 451, Pr. 800
Slip compensation Pr. 245 to Pr. 247
Stall prevention operation
Pr. 22, Pr. 23, Pr. 48, Pr. 49, Pr. 66,
Pr. 114, Pr. 115, Pr. 148, Pr. 149,
Pr. 154, Pr. 156, Pr. 157, Pr. 858,
Pr. 868
Torque limit
Pr. 22, Pr. 803, Pr. 810, Pr. 812 to
Pr. 817, Pr. 858, Pr. 868, Pr. 874
Limit the output frequency
Maximum/minimum frequency Pr. 1, Pr. 2, Pr. 18
Avoid mechanical resonance points (frequency jump) Pr. 31 to Pr. 36
Speed limit Pr. 807 to Pr. 809
Set V/F pattern
Base frequency, voltage Pr. 3, Pr. 19, Pr. 47, Pr. 113
V/F pattern matching applications Pr. 14
Adjustable 5 points V/F Pr. 71, Pr. 100 to Pr. 109
Frequency setting with
terminals (contact input)
Multi-speed setting operation
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Jog operation Pr. 15, Pr. 16
Input compensation of multi-speed and remote setting Pr. 28
Remote setting function Pr. 59