Mitsubishi Electronics FR-A701 Marine Battery User Manual


 
117
Parameter List
Parameter List
4
DRIVING THE MOTOR
Offline auto tuning
458
Second motor constant
(R1)
0.001Ω 9999
0 to 50Ω
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
459
Second motor constant
(R2)
0.001Ω 9999
0 to 50Ω
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
460
Second motor constant (L1)
0.001
Ω
(0.1mH)
9999
0 to 50
Ω
(0
to 1000mH)
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
461
Second motor constant (L2)
0.001
Ω
(0.1mH)
9999
0 to 50
Ω
(0
to 1000mH)
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
462
Second motor constant (X)
0.01Ω
(0.1%)
9999
0 to 500Ω
(0 to 100%)
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
463
Second motor auto tuning
setting/status
1 0 0, 1, 101
Set the tuning mode of the second motor. (same as
Pr. 96)
684
Tuning data unit switchover
10
0 Internal data converter value
1 Displayed in "A, Ω, mH, %".
859
Torque current
0.01A 9999
0 to 500A
Tuning data
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
860
Second motor torque
current
0.01A 9999
0 to 500A
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
89
Refer to Pr. 81.
90 to 94
Refer to Pr. 82 to Pr. 84.
Online auto tuning
95
Online auto tuning selection
10
0 Online auto tuning is not performed
1 Start-time tuning (at start-up)
2 Magnetic flux observer (normal)
574
Second motor online auto
tuning
100, 1
Select the second motor online auto tuning. (same as
Pr. 95)
96
Refer to Pr. 82 to Pr. 84.
Func
t
ion
Parameter
Name
Incre
ments
Initial
Value
Range Description
Related
parameters
Magnetic flux
Magnetic flux
Magnetic flux
Sensorless
Sensorless
Sensorless Vector
Vector
Vector
Magnetic flux
Magnetic flux
Magnetic flux
Sensorless
Sensorless
Sensorless Vector
Vector
Vector