Mitsubishi Electronics FR-A701 Marine Battery User Manual


 
116
Parameter List
Offline auto tuning
82
Motor excitation current
0.01A 9999
0 to 500A
Tuning data
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
83
Rated motor voltage
0.1V
200/
400V *
0 to 1000V
Set the rated motor voltage(V).
* The initial values differ according to the voltage level.
(200V/400V)
84
Rated motor frequency
0.01Hz 60Hz
10 to 120Hz
Set the rated motor frequency (Hz).
90
Motor constant (R1)
0.001
Ω
9999
0 to 50Ω
Tuning data
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
91
Motor constant (R2)
0.001Ω 9999
0 to 50Ω
Tuning data
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
92
Motor constant (L1)
0.001
Ω
(0.1mH)
9999
0 to 50
Ω
(0
to 1000mH)
Tuning data
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
93
Motor constant (L2)
0.001
Ω
(0.1mH)
9999
0 to 50
Ω
(0
to 1000mH)
Tuning data
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
94
Motor constant (X)
0.01Ω
(0.1%)
9999
0 to 500Ω
(0 to 100%)
Tuning data
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
96
Auto tuning setting/status
10
0 Auto tuning is not performed
1 Tuning performed without motor running
101 Tuning performed with motor running
455
Second motor excitation
current
0.01A 9999
0 to 500
A
Tuning data of the second motor
(The value measured by offline auto tuning is
automatically set.)
9999
Use the Mitsubishi motor (SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU (1500r/min series)) constants
456
Rated second motor
voltage
0.1V
200/
400V *
0 to 1000V
Set the rated voltage (V) of the second motor.
* The initial values differ according to the voltage level.
(200V/400V)
457
Rated second motor
frequency
0.01Hz 60Hz
10 to 120Hz
Set the rated frequency (Hz) of the second motor.
Func
t
ion
Parameter
Name
Incre
ments
Initial
Value
Range Description
Related
parameters
Magnetic flux
Magnetic flux
Magnetic flux
Sensorless
Sensorless
Sensorless Vector
Vector
Vector