Mitsubishi Electronics FR-A701 Marine Battery User Manual


 
193
Outline dimension drawings
7
SPECIFICATIONS
z Dedicated motor (SF-V5RU(H)) outline dimension drawings (flange type with brake)
Dimensions table (Unit: mm)
Note)1. Install the motor on the floor and use it with the shaft horizontal.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3. The size difference of top and bottom of the shaft center height is
4. The 400V class motor has -H at the end of its type name.
5. Since a brake power device is a stand-alone, install it inside the enclosure.
(This device should be arranged at the customer side.)
Frame Number 112M, 132S, 132M
SF-V5RUF(H) , ,
Frame Number 160M, 160L
SF-V5RUF(H) ,
SF-V5RU
K
SF-V5RU
K1
SF-V5RU
K3
SF-V5RU
K4
Flange
Number
Frame
No.
Mass
(kg)
Motor Shaft End
Terminal Screw Size
D KB KD KL KP LA LB LC LE LG LL LN LZ LR Q QK S T U W
U,V,W
A,B,(C)
B1,B2 G1,G2
3 FF215 112M 58 228 239 27 242 178 215 180j6 250 4 16 525 4 14.5 60 60 45 28j6 7 4 8 M6 M4 M4 M4
5 3 FF265 132S 83 266 256 27 256 197 265 230j6 300 4 20 597 4 14.5 80 80 63 38k6 8 5 10 M6 M4 M4 M4
7 5 3 FF265 132M 88 266 294 27 256 197 265 230j6 300 4 20 635 4 14.5 80 80 63 38k6 8 5 10 M6 M4 M4 M4
11 7 5 FF300 160M 151 318 318 56 330 231 300 250j6 350 5 20
735.5
4 18.5 110 110 90 42k6 8 5 12 M8 M4 M4 M4
15 11 7 3 FF300 160L 167 318 362 56 330 231 300 250j6 350 5 20
779.5
4 18.5 110 110 90 42k6 8 5 12 M8 M4 M4 M4
3KB 5KB 7KB
Section BB
W
S
U
T
Connector (for encoder)
MS3102A20-29P
QK
Q
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Suction
Exhaust
Direction of
cooling fan wind
Terminal box for cooling fan
1
2
Section
AA
LC
LB
B
B
LR
LG LE
LL
D
KB
A
LN LZ
A
1
2
LA
KD
KL
φ22
KP
Main
terminal box
VU
B2B1
W
G1 G2
CBA
For motor (U, V, W)
For cooling fan (A, B)
For brake (B1, B2)
For thermal protector (G1, G2)
Earthing
(grounding)
terminal (M4)
Earthing
(grounding)
terminal (M4)
Main terminal box Terminal box for cooling fan
11KB 15KB
Section B
B
W
S
U
T
A
A
LN LZ
2
1
LA
KD
KL
φ22
KP
Connector (for encoder)
MS3102A20-29P
QK
Q
D
Earth (ground) terminal (M8)
Mark for earthing (grounding)
Suction
Direction of
cooling fan wind
Terminal box for cooling fan
1, 2
Section
AA
LC
LB
B
B
LL
KB LR
LG
LE
Exhaust
Main
terminal box
B2B1
U
G2G1
WV
CBA
For cooling fan (A, B, C)
For motor (U, V, W)
Earthing
(grounding)
terminal (M8)
Earthing
(grounding)
terminal (M4)
For brake (B1, B2)
For thermal protector (G1, G2)
Terminal box for cooling fan
Main terminal box
indicates an inserting position of a bolt with hex head holes
for manual opening.
Make sure to earth the earth terminal of the flange section
as well as the earth terminal in the terminal box.
0
-0.5