Mitsubishi Electronics FR-A701 Marine Battery User Manual


 
50
Operation panel (FR-DU07)
4.2.3 Operation lock (Press [MODE] for an extended time (2s))
· Set "10 or 11" in Pr. 161, then press for 2s to make the setting dial and key operation invalid.
· When the setting dial and key operation are invalid, appears on the operation panel.
If dial and key operation is attempted while dial and key operation are invalid, appears. (When dial or key
is not touched for 2s, the monitor display appears.)
· To make the setting dial and key operation valid again, press for 2s.
Operation using the setting dial and key of the operation panel can be invalid to prevent parameter change, and
unexpected start or frequency setting.
POINT
Set "10 or 11" (key lock valid) in Pr.161 Frequency setting/key lock operation selection.
Functions valid even in the operation lock status
Stop and reset with .
CAUTION
Release the operation lock to release the PU stop by key operation.
1.Screen at power-ON
The monitor display appears.
Display
Operation
PU indicator is lit.
2.Press to choose the PU
operation mode.
3.Press to choose the parameter
setting mode.
Flicker ··· Parameter setting complete!!
7.Press to set.
5.Press to read the currently set value.
4.
Turn until appears.
The parameter
number read
previously
appears.
8.Press for 2s to show the key lock.
Press for 2s.
(Pr. 161)
" " (initial value) appears.
6.Turn to change it to the setting
value " ".