Mitsubishi Electronics FR-A701 Marine Battery User Manual


 
124
Parameter List
Terminal assignment of output terminal
190
RUN terminal function
selection
10
0 to 6, 8,
10 to 20,
25 to 28,
30 to 36, 39,
41 to 47,
64, 70, 84,
90 to 99,
100 to 106,
108,
110 to 116,
120,
125 to 128,
130 to 136,
139,
141 to 147,
164, 170,
184,
190 to 199,
9999
0, 100: Inverter running (RUN)
1, 101: Up to frequency (SU)
2, 102: Instantaneous power failure/undervoltage
(IPF)
3, 103: Overload warning (OL)
4, 104: Output frequency detection (FU)
5, 105: Second output frequency detection (FU2)
6, 106: Third output frequency detection (FU3)
8, 108: Electronic thermal O/L relay pre-alarm (THP)
10, 110:PU operation mode (PU)
11, 111:Inverter operation ready (RY)
12, 112:Output current detection (Y12)
13, 113:Zero current detection (Y13)
14, 114:PID lower limit (FDN)
15, 115:PID upper limit (FUP)
16, 116:PID forward/reverse rotation output (RL)
17, —: Electronic bypass MC1 (MC1)
18, —: Electronic bypass MC2 (MC2)
19, —: Electronic bypass MC3 (MC3)
20, 120:Brake opening request (BOF)
25, 125:Fan fault output (FAN)
26, 126:Heatsink overheat pre-alarm (FIN)
27, 127:Orientation complete (ORA) *
28, 128:Orientation fault (ORM) *
30, 130:Forward rotation output (Y30) *
31, 131:Reverse rotation output (Y31) *
32, 132:Regenerative status output (Y32) *
33, 133:Operation ready 2 (RY2)
34, 134:Low speed output (LS)
35, 135:Torque detection (TU)
36, 136:In-position (Y36) *
39, 139:Start time tuning completion (Y39)
41, 141:Speed detection (FB)
42, 142:Second speed detection (FB2)
43, 143:Third speed detection (FB3)
44, 144:Inverter running 2 (RUN2)
45, 145:Inverter running and start command is ON
(RUN3)
46, 146:During deceleration at occurrence of power
failure (retained until release) (Y46)
47, 147:During PID control activated (PID)
64, 164:During retry (Y64)
70, 170:PID output interruption (SLEEP)
84, 184:Position control preparation ready (RDY) *
90, 190:Life alarm (Y90)
91, 191:Fault output 3 (power-off signal) (Y91)
92, 192:Energy saving average value updated timing
(Y92)
93, 193:Current average monitor signal (Y93)
94, 194:Fault output 2 (ALM2)
95, 195:Maintenance timer signal (Y95)
96, 196:Remote output (REM)
97, 197:Alarm output 2 (ER)
98, 198:Alarm output (LF)
99, 199:Fault output (ALM)
9999: No function
0 to 99: Positive logic
100 to 199: Negative logic
* Available only when used with the FR-A7AP/FR-A7AL
(option).
191
SU terminal function
selection
11
192
IPF terminal function
selection
12
193
OL terminal function
selection
13
194
FU terminal function
selection
14
195
ABC1 terminal function
selection
199
0 to 6, 8,
10 to 20,
25 to 28,
30 to 36, 39,
41 to 47, 64,
70, 84, 90,
91,
94 to 99,
100 to 106,
108,
110 to 116,
120,
125 to 128,
130 to 136,
139,
141 to 147,
164, 170,
184, 190,
191, 194 to
199, 9999
196
ABC2 terminal function
selection
1 9999
232 to 239
Refer to Pr. 4 to Pr. 6.
240
Refer to Pr. 72.
241
Refer to Pr. 125 and Pr. 126.
242, 243
Refer to Pr. 73.
Func
t
ion
Parameter
Name
Incre
ments
Initial
Value
Range Description
Related
parameters