Mitsubishi Electronics FR-A701 Marine Battery User Manual


 
105
Parameter List
Parameter List
4
DRIVING THE MOTOR
V/F pattern matching
applications
14
Load pattern selection
10
0 For constant-torque load
1 For variable-torque load
2
For constant-torque lift
Boost for reverse rotation
0%
3
Boost for forward rotation
0%
4
RT signal ON.... For constant-torque load (Same as
in setting 0)
RT signal OFF
.. For constant-torque lift
Boost for reverse rotation 0%
(Same as in setting 2)
5
RT signal ON.... For constant-torque load (Same as
in setting 0)
RT signal OFF
.. For constant-torque lift
Boost for forward rotation 0%
(Same as in setting 3)
Jog operation
15
Jog frequency
0.01Hz 5Hz 0 to 400Hz Set the frequency for jog operation.
16
Jog acceleration/
deceleration time
0.1/
0.01s
0.5s
0 to 3600/
360s
Set the acceleration/deceleration time for jog
operation. Set the time taken to reach the frequency
set in Pr. 20 Acceleration/deceleration reference
frequency for acceleration/deceleration time. (Initial
value is 60Hz)
In addition, acceleration/deceleration time can not be
set separately.
Logic selection
of output stop
signal (MRS)
17
MRS input selection
10
0 Open input always
2
Normally closed input (NC contact input
specifications)
4
External terminal:Normally closed input (NC contact
input specifications)
Communication :Normally open input
18
Refer to Pr. 1 and Pr. 2.
19
Refer to Pr. 3.
20, 21
Refer to Pr. 7 and Pr. 8.
Func
t
ion
Parameter
Name
Incre
ments
Initial
Value
Range Description
Related
parameters
V/F
V/F
V/F