Mitsubishi Electronics FR-A701 Marine Battery User Manual


 
123
Parameter List
Parameter List
4
DRIVING THE MOTOR
Function assignment of input terminal
178
STF terminal function
selection
160
0 to 9,
12 to 20,
22 to 28,
42 to 44, 60,
62, 64 to 69,
74, 9999
0: Low-speed operation command (RL)
1: Middle-speed operation command (RM)
2: High-speed operation command (RH)
3: Second function selection (RT)
4: Terminal 4 input selection (AU)
5: Jog operation selection (JOG)
6: Selection of automatic restart after instantaneous
power failure, flying start (CS)
7: External thermal relay input (OH)
8: 15-speed selection (REX)
9: Third function (X9)
12: PU operation external interlock (X12)
13: External DC injection brake start (X13)
14: PID control valid terminal (X14)
15: Brake opening completion signal (BRI)
16: PU/External operation switchover (X16)
17: Load pattern selection forward/reverse rotation
boost (X17)
18: V/F switchover (X18)
19: Load torque high-speed frequency (X19)
20: S-pattern acceleration/deceleration C switching
terminal (X20)
22: Orientation command (X22)
23: Pre-excitation (LX)
24: Output stop (MRS)
25: Start self-holding selection (STOP)
26: Control mode changing (MC)
27: Torque limit selection (TL)
28: Start time tuning (X28)
42: Torque bias selection 1 (X42) *
43: Torque bias selection 2 (X43) *
44: P/PI control switchover (X44)
60: Forward rotation command (STF) (assigned to
STF terminal (Pr. 178) only)
61: Reverse rotation command (STR) (assigned to
STR terminal (Pr. 179) only)
62: Inverter reset (RES)
63: PTC thermistor input (PTC) (assigned to AU
terminal (Pr. 184) only)
64: PID forward/reverse action switchover (X64)
65: PU/NET operation switchover (X65)
66: External/NET operation switchover (X66)
67: Command source switchover (X67)
68: Simple position pulse train sign (NP) *
69: Simple position droop pulse clear (CLR) *
74: Magnetic flux decay output shutoff (X74)
9999:No function
* Available only when used with the FR-A7AP/FR-A7AL
(option).
179
STR terminal function
selection
161
0 to 9,
12 to 20,
22 to 28,
42 to 44, 61,
62, 64 to 69,
74, 9999
180
RL terminal function
selection
10
0 to 9,
12 to 20,
22 to 28,
42 to 44, 62,
64 to 69, 74,
9999
181
RM terminal function
selection
11
182
RH terminal function
selection
12
183
RT terminal function
selection
13
184
AU terminal function
selection
14
0 to 9,
12 to 20,
22 to 28,
42 to 44,
62 to 69, 74,
9999
185
JOG terminal function
selection
15
0 to 9,
12 to 20,
22 to 28,
42 to 44, 62,
64 to 69, 74,
9999
186
CS terminal function
selection
16
187
MRS terminal function
selection
124
188
STOP terminal function
selection
125
189
RES terminal function
selection
162
Func
t
ion
Parameter
Name
Incre
ments
Initial
Value
Range Description
Related