Parameter List
Parameter List
4
DRIVING THE MOTOR
Output frequency detection and motor speed
(SU, FU, FU2, FU3, FB, FB2, FB3, LS signal)
41
Up-to-frequency sensitivity
0.1% 10% 0 to 100% Set the level where the SU signal turns on.
42
Output frequency detection
0.01Hz 6Hz 0 to 400Hz Set the frequency where the FU (FB) signal turns on.
43
Output frequency detection
for reverse rotation
0.01Hz 9999
0 to 400Hz
Set the frequency where the FU (FB) signal turns on
in reverse rotation.
9999 Same as Pr. 42 setting
50
Second output frequency
detection
0.01Hz 30Hz 0 to 400Hz
Set the frequency where the FU2 (FB2) signal turns
on.
116
Third output frequency
detection
0.01Hz 60Hz 0 to 400Hz
Set the frequency where the FU3 (FB3) signal turns
on.
865
Low speed detection
0.01Hz 1.5Hz 0 to 400Hz Set the frequency where the LS signal turns on.
44, 45
Refer to Pr. 7 and Pr. 8.
46
Refer to Pr. 0.
47
Refer to Pr. 3.
48, 49
Refer to Pr. 22 and Pr. 23.
50
Refer to Pr. 41 to Pr. 43.
51
Refer to Pr. 9.
Func
t
ion