Mitsubishi Electronics FR-E500 Marine Radio User Manual


 
PARAMETERS
89
How to make a restart after a stop by the
STOP
RESET
key on the PU
Parameter unit (FR-PU04)
1) After completion of deceleration to a stop, switch off the STF or STR signal.
2) Press the
EXT
key.
3) Switch on the STF or STR signal.
Stop and restart example for DeviceNet operation
STF ON
(STR) OFF
Time
Parameter unit
(FR-PU04)
Speed
key
key
SET
STOP
RESET
The other way of making a restart other than the above method is to perform a power-
reset or to make a reset with the inverter reset terminal.
Note:1. By entering the reset signal (RES) during operation, the inverter shuts off
output while it is reset, the data of the electronic overcurrent protection and
regenerative brake duty are reset, and the motor coasts.
2. The PU disconnection detection function judges that the PU is disconnected
when it is removed from the inverter for more than 1 second. If the PU had
been disconnected before power-on, it is not judged as an alarm.
3. To resume operation, reset the inverter after confirming that the PU is
connected securely.
4. The Pr. 75 value can be set any time. Also, if parameter (all) clear is
executed, this setting will not return to the initial value.
5. When the inverter is stopped by the PU stop function, PS is displayed but an
alarm is not output.
When the PU connector is used for RS-485 communication operation, the
reset selection and PU stop selection functions are valid but the PU
disconnection detection function is invalid.
CAUTION
Do not reset the inverter with the start signal on.
Otherwise, the motor will start instantly after resetting, leading to
potentially hazardous conditions.