158
2. Class 0x03 - DeviceNet Object
(1) Class 0x03 Attributes - Instance 0
Note: Not applicable to the FR-E500KND.
(2) Class 0x03 Services - Instance 0
Note: Not applicable to the FR-E500KND.
(3) Class 0x03 Instance Attributes - Instance 1
No. Access Attribute Value
1 Get/Set Node Address Setting (Note) 0 to 63
2 Get/Set
Baud Rate Setting (Note) (0: 125kbps, 1:
250kbps, 2: 500kbps)
0 to 2
3 Get/Set
Bus Off Interrupt
0: Hold CAN chip in reset state on
detection of Bus Off.
1: Reset CAN chip and continues
communication on detection of Bus
Off.
0 to 1
4 Get/Set
Bus Off Counter (the number of times
when the CAN chip resulted in bus off is
counted)
0 to 255
5 Get Allocation Information 0 to 0xFFFF
8 Get MAC ID Switch Value 0 to 63
9 Get Actual Value of Baud Rate 0 to 2
Note: Class 0x67 Instance 1 Attributes 45 and 46 may also be used to perform
read.
(4) Class 0x03 Instance Services - Instance 1
Service Code Service
0x4B Allocate
0x4C Release
0x0E Get Attribute Single
0x10 Set Attribute Single