PARAMETERS
126
Definitions of each registration
Name Description Definition
Default
setting
Watch dog
timeout operation
(WDA) (Note)
DeviceNet connection object
(Class code 0x05)
Instance 2 attribute 12
0 = Transition to timeout
1 = Automatic delete
2 = Automatic reset
0
DN fault mode
Supports the control
management object. (Class
code 0x29) Instance attribute
16, DN fault mode
0 = Fault and stop
1 = Ignore
0
Input assembly
Value of assembly ID used in
connection object. (Class code
0x05) Instance attribute 16,
consumed_connection_path
Assembly ID
0 = 70
1 = 71
6 = 176
8 = 150
1
Output assembly
Assembly ID value used in
connection object. (Class code
0x05) Instance attribute 14,
produced_connection_path
Assembly instance ID
0 = 20
1 = 21
6 = 126
8 = 100
1
Baud rate
DeviceNet object value (Class
code 0x03) Instance attribute 2,
baud rate
0 = 125 kbps
1 = 250 kbps
2 = 500 kbps
0
Device address
DeviceNet object value (Class
0x03) Instance attribute 1, MAC
ID
Node address; Range is 0 to 63
(same definition as attribute)
63
Address key Internal confirmation 1010-setting value; No others 1010
Baud rate key Internal confirmation 1010-setting value; No others 0101
Note: The parameter setting will be changed back to the factory setting (0) when
reconnected after a disconnection.
Normally, these parameters are not accessed via the PU. Instead, a DeviceNet user
will access the various fields of these parameters via DeviceNet and set them
according to the table above.
Pr. 990 to Pr. 991
&
&&
&
Refer to Pr. 145.