PARAMETERS
79
<Setting>
Refer to the figure below and set the corresponding parameters:
!
When Pr. 43
9999, the Pr. 42 setting applies to forward rotation and the Pr. 43
setting applies to reverse rotation.
!
Assign the terminal used for FU signal output with Pr. 192 "A, B, C terminal (ABC)
function selection".
Refer to page 120 for Pr. 192 "A, B, C terminal (ABC) function selection".
!
The DeviceNet output is the 6-bit inverter status.
Pr.42
Pr.43
Output
frequency (Hz)
Output signal
FU
Time
OFF
ON
OFF
ON
OFF
Reverse
rotation
Forward
rotation
Note: Changing the terminal assignment using Pr. 192 may affect the other
functions. Make setting after confirming the function of each terminal.
Pr. 44, Pr. 45
&
&&
&
Refer to Pr. 7.
Pr. 46
&
&&
&
Refer to Pr. 0.
Pr. 47
&
&&
&
Refer to Pr. 3.
Pr. 48
&
&&
&
Refer to Pr. 9.
"
Monitor display (Pr. 52, Pr. 54)
4.2.17 Monitor display (Pr. 52)
Pr. 52 "PU main display data selection"
You can select the signals shown on the parameter unit (FR-PU04) main display
screen.
Parameter
Number
Factory
Setting
Setting
Range
52 0 0, 23, 100
Pr. 37 "speed display"
Pr. 171 "actual operation hour
meter clear"
Related parameters