The following variables and parameters are specific to the FR-E500KND.
FR-E500KND System Environment Variables
No. Access Attribute Value
101 Set Inverter reset 1
102 Set Parameter Clear 0x965A
103 Set Parameter All Clear 0x99AA
105 Set Parameter Clear (Ex Com Pr) 0x5A96
106 Set Parameter All Clear (Ex Com Pr) 0xAA99
112 Get/Set Running Frequency (RAM) (Note) 30.00Hz
113 Set
Running Frequency (E
2
PROM) (Note)
30.00Hz
114 Get/Set Inverter Status/Control Input Command 0 to 0xFFFF
120 Get/Set
Operating Mode/Inverter Config
(1) Get 1: PU operation
4: DeviceNet communication
operation
(2) Set 0x11: PU operation
0x14: DeviceNet communication
operation
Note: Write to No.112 and No.113 can be read out from No.112.
FR-E500KND
Real Time Parameters
No. Access Attribute Value
141 Get/Set
Alarm History 1 (Note)/Alarm History All
Clear
0 to 0xFFFF
142 Get Alarm History 2 (Note) 0 to 0xFFFF
143 Get Alarm History 3 (Note) 0 to 0xFFFF
144 Get Alarm History 4 (Note) 0 to 0xFFFF
145 Get Alarm History 5 (Note) 0 to 0xFFFF
146 Get Alarm History 6 (Note) 0 to 0xFFFF
147 Get Alarm History 7 (Note) 0 to 0xFFFF
148 Get Alarm History 8 (Note) 0 to 0xFFFF
170 Get
Output frequency
(Minimum setting increments: 0.01Hz)
0 to 0xFFFF
171 Get
Output Current
(Minimum setting increments: 0.01A)
0 to 0xFFFF
172 Get
Output Voltage
(Minimum setting increments: 0.1V)
0 to 0xFFFF
Note: For the alarm history, refer to the alarm code list on the next page.