Mitsubishi Electronics FR-E500 Marine Radio User Manual


 
PARAMETERS
112
"
" PID control (Pr. 128 to Pr. 134)
4.2.30 Settings for connection of FR-PU04 (Pr. 145, Pr. 990, Pr. 991)
Pr. 145 "Parameter unit display language selection"
Pr. 990 "Buzzer beep control"
Pr. 991 "LCD contrast"
!
!!
!
All of the below parameters are only applicable when using the FR-PU04 parameter
unit.
By setting the Pr. 145 "Parameter unit display language selection" value, you can
select the language displayed on the parameter unit.
Pr. 145 Setting Display Language
0 Japanese (factory setting)
1 English
2German
3 French
4 Spanish
5 Italian
6 Swedish
7 Finnish
By setting the Pr. 990 "Buzzer beep control" value, you can select whether the "beep"
is sounded or not when you press any of the parameter unit key.
Pr. 990 Setting Description
0 No sound
1 Sound generated (factory setting)
By setting the Pr. 991 "LCD contrast" value, you can adjust the contrast of the
parameter unit LCD.
Pr. 991 Setting
0 to 63
[0] [63][53]
Bright Dar
k
Factory setting
Note: The LCD contrast setting will not be stored until the
WRITE
key is pressed.
4