Mitsubishi Electronics FR-E500 Marine Radio User Manual


 
179
10. Response Timing
Item 1
Polling-Reading and Request Without Changing State:
Explicit Messaging (G2 & G3)-Get-Attribute-Reading Data:
Request
Response Time = 1 ms
Response
Item 2.
Polling-Writing and Request With Changing State:
Explicit Messaging (G2 & G3)-Set-Attribute-Writing Data
(Excluding Items 3 & 4):
Request
Response Time = 30 ms
Response
Item 3.
PrClr, PrAllClr, PrClr(ECP), PrAllClr(ECP):
Request
Response Time = 5 s
Response
11. Recommendation For Software Developers
For software developers only:
a. Make a handshake procedure, send a request, wait for response, then go to next
request.
b. Set the waiting time between messages on the basis of the above FR-E500KND
specifications. For example, set 1ms for read and 30ms for write.