Mitsubishi Electronics FR-E500 Marine Radio User Manual


 
PARAMETERS
107
<Setting items and set data>
After completion of parameter settings, set the instruction codes and data then start
communication from the computer to allow various types of operation control and
monitoring.
No.
Item
Instruction
Code
Description
Number
of Data
Digits
(Data
code
FF=1)
Read
H7B
H0001: DeviceNet operation
H0002: Communication operation
1
Operation
mode
Write
HFB
H0001: DeviceNet operation
H0002: Communication operation
4 digits
Output frequency
[speed]
H6F
H0000 to HFFFF:Output frequency
(hexadecimal) in 0.01Hz
increments
[Speed (hexadecimal) in
r/min increments if Pr. 37 = 1
to 9998]
4 digits
(6 digits)
Output current H70
H0000 to HFFFF: Output current
(hexadecimal) in 0.01A
increments
4 digits
Output voltage H71
H0000 to HFFFF: Output voltage
(hexadecimal) in 0.1V
increments
4 digits
H0000 to HFFFF: Two most recent alarm
definitions
Alarm definition display
example (instruction code
H74)
b15
b8b7
b0
001100 0 0 00000011
Previous alarm
(H30)
Most recent alarm
(HA0)
Alarm data
Data
Description
Data
Description
H00 No alarm H60 OLT
H10 OC1 H70 BE
H11 OC2 H80 GF
H12 OC3 H81 LF
H20 OV1 H90 OHT
H21 OV2 HA0 OPT
H22 OV3 HB0 PE
H30 THT HB1 PUE
H31 THM HB2 RET
H40 FIN
2
Monitoring
Alarm definition
H74 to
H77
4 digits
3 Run command HFA
b7
000000 01
b0
b0 :
b1 : Forward rotation (STF)
b2 : Reverse rotation (STR)
b3 :
b4 :
b5 :
b6 :
b7 :
[Example 1] H02 ... Forward rotation
[Example 2] H00 ... Stop
[For example 1]
2 digits