Mitsubishi Electronics FR-E500 Marine Radio User Manual


 
APPENDIX 1 Object Map
157
APPENDIX
APPENDIX 1 Object Map
This section describes the DeviceNet object definitions of the FR-E500KND. For details
of the definitions, please consult the DeviceNet documentation available from ODVA.
In the following tables, Get and Set mean:
Get: Read from inverter
Set: Write to inverter
1. Class 0x01 - Identity Object
(1) Class 0x01 Attributes - Instance 0
No. Access Attribute Type Value
1 Get Revision Word 1
2 Get Maximum Instance Word 1
6 Get Maximum Class Attributes Word 7
7 Get Maximum Instance Attributes Word 7
(2) Class 0x01 Services - Instance 0
Service Code Service
0x0E Get Attribute Single
(3) Class 0x01 Instance Attributes - Instance 1
No. Access Attribute Type Value
1 Get Vendor ID Word 82 (0x0052)
2 Get Product Type Word 0x0002
3 Get Product Code Word 501 (0x1F5)
4 Get Revision Word 1.YYY (Note 1)
5 Get Status Word 0x0000
6 Get Serial Number Word xxxxxxxx (Note 2)
7 Get Name Word E500 (Note 3)
Note 1. The upper byte of the read hexadecimal word data indicates the integer
part (major revision) and its lower byte indicates the fraction part (minor
revision). For example, the read data of 0x010A means version 1.010.
2. The value changes with the product.
3. The actual data stored are 0x04, 0x45, 0x35, 0x30 and 0x30. The first
0x04 indicates the 4-byte data and the others indicate "E500" in ASCII
(4) Class 0x01 Instance Services - Instance 1
Service Code Service Description
0x05 Reset
0-Power Reset
1-Parameter All Clear and Power Reset
0x0E Get Attribute Single