Mitsubishi Electronics FR-E500 Marine Radio User Manual


 
PARAMETERS
118
Pr. 52 "PU main display data
selection"
Related parameter
4.2.35 Actual operation hour meter clear (Pr. 171)
Pr. 171 "actual operation hour meter
clear"
You can clear the monitor (actual operation hour) value which is selected when Pr. 52
is "23".
Parameter
Number
Factory
Setting
Setting
Range
171 0 0
<Setting>
Write "0" in the parameter to clear the actual operation hour.
Pr. 173 to Pr. 176
&
&&
&
Refer to Pr. 160.
4.2.36 Input terminal (DeviceNet input) function selection (Pr. 180
to Pr. 183)
"
Input terminal function selection (Pr. 180 to Pr. 183)
Pr. 180 "(RL) function selection"
Pr. 181 "(RM) function selection"
Pr. 182 "(RH) function selection"
Pr. 183 "MRS terminal (MRS) function selection"
Use these parameters to select/change the input terminal (DeviceNet input) functions.
Parameter
Number
Terminal
(DeviceNet
input) Symbol
Factory
Setting
Factory-Set Terminal
Function
Setting
Range
Remarks
180 (RL) 0
Low-speed operation
command (RL)
0 to 3, 6,
8, 18
181 (RM) 1
Middle-speed operation
command (RM)
0 to 3, 6,
8, 18
182 (RH) 2
High-speed operation
command (RH)
0 to 3, 6,
8, 18
DeviceNet
input
183 MRS (MRS) 6 Output shut-off (MRS)
0 to 3,
6 to 8, 18
DeviceNet
input, input
terminal
4