Mitsubishi Electronics FR-E500 Marine Radio User Manual


 
4.1 Parameter List
PARAMETERS
55
4 PARAMETERS
4.1 Parameter List
4.1.1 Parameter list
Func-
tion
Param-
eter
Number
Name
Setting
Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Custo-
mer
Setting
0 Torque boost (Note 1) 0 to 30% 0.1% 6% 62
1 Maximum frequency 0 to 120Hz 0.01Hz 120Hz 63
2 Minimum frequency 0 to 120Hz 0.01Hz 0Hz 63
3 Base frequency (Note 1) 0 to 400Hz 0.01Hz 60Hz 64
4
Multi-speed setting
(high speed)
0 to 400Hz 0.01Hz 60Hz 65
5
Multi-speed setting
(middle speed)
0 to 400Hz 0.01Hz 30Hz 65
6
Multi-speed setting
(low speed)
0 to 400Hz 0.01Hz 10Hz 65
7 Acceleration time
0 to 3600 s/
0 to 360 s
0.1 s/0.01 s
5 s/10s
(Note 2)
66
8 Deceleration time
0 to 3600 s/
0 to 360 s
0.1 s/0.01 s
5 s/10s
(Note 2)
66
Basic functions
9 Electronic thermal O/L relay 0 to 500A 0.01A
Rated
output
current
(Note 3)
68
10
DC injection brake
operation frequency
0 to 120Hz 0.01Hz 3Hz 69
11
DC injection brake
operation time
0 to 10 s 0.1 s 0.5 s 69
12 DC injection brake voltage 0 to 30% 0.1% 6% 69
13 Starting frequency 0 to 60Hz 0.01Hz 0.5Hz 70
14
Load pattern selection
(Note 1)
0 to 3 1 0 71
18
High-speed maximum
frequency
120 to
400Hz
0.1Hz 120Hz 63
19
Base frequency voltage
(Note 1)
0 to 1000V,
8888,9999
0.1V 9999 64
20
Acceleration/deceleration
reference frequency
1 to 400Hz 0.01Hz 60Hz 66
21
Acceleration/deceleration
time increments
0, 1 1 0 66
22
Stall prevention operation
level
0 to 200% 0.1% 150% 72
23
Stall prevention operation
level compensation factor at
double speed
(Note 4)
0 to 200%,
9999
0.1% 9999 72
24
Multi-speed setting
(speed 4)
0 to 400Hz,
9999
0.01Hz 9999 65
25
Multi-speed setting
(speed 5)
0 to 400Hz,
9999
0.01Hz 9999 65
26
Multi-speed setting
(speed 6)
0 to 400Hz,
9999
0.01Hz 9999 65
27
Multi-speed setting
(speed 7)
0 to 400Hz,
9999
0.01Hz 9999 65
29
Acceleration/deceleration
pattern
0, 1, 2 1 0 74
Standard operation functions
30
Regenerative function
selection
0, 1 1 0 75
Parameter List