PARAMETERS
56
Func-
tion
Param-
eter
Number
Name
Setting
Range
Minimum
Setting
Increments
Factory
Setting
Refer
To:
Custo-
mer
Setting
31 Frequency jump 1A
0 to 400Hz,
9999
0.01Hz 9999 76
32 Frequency jump 1B
0 to 400Hz,
9999
0.01Hz 9999 76
33 Frequency jump 2A
0 to 400Hz,
9999
0.01Hz 9999 76
34 Frequency jump 2B
0 to 400Hz,
9999
0.01Hz 9999 76
35 Frequency jump 3A
0 to 400Hz,
9999
0.01Hz 9999 76
36 Frequency jump 3B
0 to 400Hz,
9999
0.01Hz 9999 76
Standard operation functions
37 Speed display
0,
0.01 to 9998
0.001 r/min 0 77
41 Up-to-frequency sensitivity 0 to 100% 0.1% 10% 78
42 Output frequency detection 0 to 400Hz 0.01Hz 6Hz 78
Output
terminal
functions
43
Output frequency detection
for reverse rotation
0 to 400Hz,
9999
0.01Hz 9999 78
44
Second acceleration/
deceleration time
0 to 3600 s
/0 to 360 s
0.1 s/0.01 s 5s 66
45 Second deceleration time
0 to 3600 s
/0 to 360 s,
9999
0.1 s/0.01 s 9999 66
46
Second torque boost
(Note 1)
0 to 30%,
9999
0.1% 9999 62
47
Second V/F (base
frequency) (Note 1)
0 to 400Hz,
9999
0.01Hz 9999 64
Second functions
48
Second electronic
overcurrent protection
0 to 500A,
9999
0.01A 9999 68
Display
functions
52
PU main display data
selection
0, 23, 100 1 0 79
57 Restart coasting time
0 to 5 s,
9999
0.1 s 9999 81
Automatic
restart
functions
58 Restart cushion time 0 to 60 s 0.1 s 1.0 s 81
60
Shortest acceleration/
deceleration mode
0, 1, 2, 11,
12
1082
61
Reference I for intelligent
mode
0 to 500A,
9999
0.01A 9999 82
62
ref. I for intelligent mode
accel
0 to 200%,
9999
1% 9999 82
63
ref. I for intelligent mode
decel
0 to 200%,
9999
1% 9999 82
65 Retry selection 0, 1, 2, 3 1 0 84
66
Stall prevention operation
level reduction starting
frequency (Note 4)
0 to 400Hz 0.01Hz 60Hz 72
67
Number of retries at alarm
occurrence
0 to 10,
101 to 110
1084
68 Retry waiting time 0.1 to 360 s 0.1 s 1 s 84
69 Retry count display erasure 0 1 0 84
Operation selection functions
70
Special regenerative brake
duty
0 to 30% 0.1% 0% 75
Parameter List
4