PARAMETERS
109
No.
Item
Instruction
Code
Description
Number
of Data
Digits
(Data
code
FF=1)
Read H7F
11
Link
parameter
expansion
setting
Write HFF
H00 to H6C and H80 to HEC parameter values
are changed.
H00: Pr. 0 to Pr. 96 values are accessible.
H01: Pr. 117 to Pr. 156 values are accessible.
H02: Pr. 160 to Pr. 192 and Pr. 232 to Pr. 250
values are accessible.
H03: Pr. 345 to Pr. 348 values are accessible.
H09: Pr. 990, Pr. 991 values are accessible.
2 digits
REMARKS
For the instruction codes HFF, their set values are held once they are written, but