Mitsubishi Electronics FR-E500 Marine Radio User Manual


 
PARAMETERS
66
Note:1. The multi-speeds can also be set in the PU or DeviceNet operation mode.
2. For 3-s
p
eed settin
g
, if two or three s
p
eeds are simultaneousl
y
selected,
priority is given to the frequency setting of the lower signal.
3. Pr. 24 to Pr. 27 and Pr. 232 to Pr. 239 settin
g
s have no
p
riorit
y
between
them.
4. The parameter values can be changed during operation.
5. When in
p
ut terminal
(
DeviceNet in
p
ut
)
assi
g
nment is chan
g
ed usin
g
Pr. 180
to Pr. 183, the other functions ma
y
be affected. Check the functions of the
corresponding terminals (DeviceNet input) before making setting.
4.2.5 Acceleration/deceleration time (Pr. 7, Pr. 8, Pr. 20, Pr. 21,
Pr. 44, Pr. 45)
"
Acceleration/deceleration time (Pr. 7, Pr. 8, Pr. 20, Pr. 21, Pr. 44, Pr. 45)
Pr. 7 "acceleration time"
Pr. 8 "deceleration time"
Pr. 20 "acceleration/deceleration reference frequency"
Pr. 21 "acceleration/deceleration time increments"
Pr. 44 "second acceleration/deceleration time"
Pr. 45 "second deceleration time"
Used to set motor acceleration/deceleration time.
Set a larger value for a slower speed increase/decrease or a smaller value for a faster
speed increase/decrease.
Parameter
Number
Factory Setting Setting Range Remarks
0.1K to 3.7K 5s
7
5.5K, 7.5K 10s
0 to 3600s/0 to 360s
0.1K to 3.7K 5s
8
5.5K, 7.5K 10s
0 to 3600s/0 to 360s
20 60Hz 1 to 400Hz
21 0 0, 1
0: 0 to 3600s
1: 0 to 360s
44 5s 0 to 3600s/0 to 360s
45 9999
0 to 3600s/
0 to 360s, 9999
9999: acceleration time =
deceleration time
Time
Pr.20
Pr.7
Pr.44
Pr.8
Pr.45
Running frequency
Acceleration Deceleration
Output frequency (Hz)
Pr. 3 "base frequency"
Pr. 29 "acceleration/deceleration
pattern"
Related
p
arameters
4