Mitsubishi Electronics FR-E500 Marine Radio User Manual


 
PARAMETERS
84
"
" Retry function (Pr. 65, Pr. 67, Pr. 68, Pr. 69)
4.2.20 Retry function (Pr. 65, Pr. 67 to Pr. 69)
Pr. 65 "retry selection"
Pr. 67 "number of retries at alarm occurrence"
Pr. 68 "retry waiting time"
Pr. 69 "retry count display erasure"
When any protective function (major fault) is activated and the inverter stops its output,
the inverter itself resets automatically and performs retries. You can select whether
retry is made or not, alarms reset for retry, number of retries made, and waiting time.
Parameter
Number
Factory
Setting
Setting Range
65 0 0 to 3
67 0 0 to 10, 101 to 110
68 1 s 0.1 to 360 s
69 0 0
<Setting>
Use Pr. 65 to select the protective functions (major faults) which execute retry.
Errors Reset for Retry Setting
Function name 0 1 2 3
During acceleration
(
OC1
)
"" "
Durin
g
constant speed
(
OC2
)
"" "
Overcurrent shut-off
During deceleration
During stop
(
OC3
)
"" "
During acceleration
(
OV1
)
"""
Durin
g
constant speed
(
OV2
)
"""
Regenerative overvoltage
shut-off
During deceleration
During stop
(
OV3
)
"""
Motor (THM)
"
Overload shut-off
(Electronic overcurrent
protection)
Inverter (THT)
"
Fin overheat (FIN)
Brake transistor fault detection (BE)
"
Output side ground fault overcurrent protection (GF)
"
External thermal relay operation (OHT)
"
Power limit stall prevention (OLT)
"
Communication error (OPT)
"
Parameter error (PE)
"
PU disconnection occurrence (PUE)
Retry count exceeded (RET)
CPU error (CPU)
Note:
"
indicates the retry items selected.
4