Operation selection functions 1 (Pr. 17 to Pr. 37)
PARAMETERS
3
Pr. 29 = 4 (S-pattern acceleration/deceleration C)
With the S-pattern acceleration/deceleration C switch signal (X20), an acceleration/deceleration curve S-pattern 1
or S-pattern 2 can be selected.
As the acceleration/deceleration time during acceleration/deceleration, set the percentage to the acceleration/
deceleration time T in Pr. 380 to Pr. 383.
Parameter setting (%) = Ts / T ×100%
Operation
During Acceleration During Deceleration
X20 Signal
OFF Pr. 380 "acceleration S pattern 1" Pr. 381 "deceleration S pattern 1"
ON Pr. 382 "acceleration S pattern 2" Pr. 383 "deceleration S pattern 2"
REMARKS
At a start, the motor starts at Pr. 13 "starting speed" when the start signal turns on.
If there is a difference between the speed command and speed at a start of deceleration due to torque limit operation etc.,
the speed command is matched with the speed to make deceleration.
Related parameters
Base frequency setting (acceleration/deceleration time setting) Pr. 3 "base frequency" (Refer to page 77.)
Pr. 20 "acceleration/deceleration reference speed"
Refer to page 78.
X20 signal setting when Pr. 29 = 4 (S-pattern acceleration/deceleration switch)
Pr. 180 to Pr. 187 (input terminal function
selection) (Refer to page 150.)
Starting speed setting
Pr. 13 "starting speed" (Refer to page 84.)
Pr.380
Pr.381
OFF
OFF
Pr.382
Pr.382
Pr.383
Pr.383
ON
ON
Pr.380
Pr.381
S-pattern C switch
(X20)
Set speed
CAUTION
Change the S pattern acceleration/
deceleration C switch (X20) after the speed
becomes constant. S pattern operation
before switching continues even if the X20 is
changed during acceleration or
deceleration.
S-pattern acceleration
Linear acceleration
Ts
T
Ts