Mitsubishi Electronics FR-V520-1.5K to 55K Marine Battery User Manual


 
175
Control system functions (Pr. 818 to Pr. 837)
PARAMETERS
3
3.32 Control system functions (Pr. 818 to Pr. 837)
3.32.1 Easy gain tuning selection (Pr. 818, Pr. 819 )
Refer to the Instruction Manual (basic) for details.
3.32.2 Speed loop proportional gain setting (Pr. 820, Pr. 830 )
z Set the proportional gain of the speed loop.
Increasing the gain enhances the speed response level and decreases the speed fluctuation relative to
disturbance, but a too large gain will produce vibration and/or sound.
z The setting range of Pr. 820 "speed control P gain 1" and Pr. 830 "speed control P gain 2" is 0 to 1000% and the
factory setting is 60%. For general adjustment, set them within the range of 20 to 200%.
3.32.3 Speed control integral time setting (Pr. 821, Pr. 831 )
z Set the integral compensation time of the speed loop.
If speed fluctuation occurs relative to disturbance, decreasing the value shortens the recovery time, but a too
small value will cause a speed overshoot.
A large value improves stability but increases the recovery time (response time) and may cause an undershoot.
3.32.4 Speed setting circuit filter function (Pr. 822, Pr. 832 )
The ratio of load inertia to motor inertia (load inertia moment ratio) is estimated in real time from the torque
command and speed during motor operation, and this value is used to automatically set the optimum gain for
speed/position control, reducing the time and effort of making gain adjustment.
Parameter Name Factory Setting Setting Range
818 Easy gain tuning response level setting 2 1 to 15
819 Easy gain tuning selection 0
0 No tuning
1 With load estimation
2 Manual load input
Related parameters
Adjusted gains Pr. 820 "speed control P gain 1", Pr. 821 "speed control integral time 1", Pr. 828 "model speed control gain",
Pr. 422 "position loop gain"
Adjusted load inertia ratio
Pr. 880 "load inertia ratio"
Parameter Name Factory Setting Setting Range Remarks
820 Speed control P gain 1 (when RT signal is off) 60% 0 to 1000%
Extended mode
830 Speed control P gain 2 (when RT signal is on) 9999
0 to 1000%
, 9999
REMARKS
1. The response level will be worse when the coupling is loose.
2. When performing positioning, increase the setting to enhance accuracy.
3. Decrease the setting when there is gear backlash, etc.
Parameter Name Factory Setting Setting Range Remarks
821 Speed control integral time 1 (when RT signal is off) 0.333s 0 to 20s
Extended mode
831 Speed control integral time 2 (when RT signal is on) 9999
0 to 20s
, 9999
REMARKS
You can switch between PI control and P control under speed control using the X44 signal. (Refer to page 34.)
Set the time constant of the primary delay filter relative to the external speed command (analog input
command).
Set a large time constant when you want to delay the tracking of the speed command, when the analog input
voltage fluctuates, etc.
Parameter Name Factory Setting Setting Range Remarks
822 Speed setting filter 1 (when RT signal is off) 0s (without filter) 0 to 5s
Extended mode
832 Speed setting filter 2 (when RT signal is on) 9999
0 to 5s
, 9999
speed position
speed position
speed position
speed position