Mitsubishi Electronics FR-V520-1.5K to 55K Marine Battery User Manual


 
81
Basic functions (Pr. 0 to Pr. 9)
PARAMETERS
3
REMARKS
When running two motors with one inverter, you can set the electronic thermal relay function of each inverter.
... Output current value is used to perform integration processing.
... Output current is assumed as 0A to perform integration processing. (cooling processing)
... Electronic thermal relay function is not activated.
It is valid for controlling one motor with one inverter in two different control systems.
It is valid for controlling the first motor with an external thermal relay and the second motor with an electronic thermal relay
function.
Related parameters
When constant-torque motor is used Pr. 71 "applied motor", Pr. 450 "second applied motor" (Refer to page 111.)
Use of second motor
Pr. 450 "second applied motor" (Refer to page 111.)
RT signal setting
Set "3" in any of Pr. 180 to Pr. 183 and Pr. 187 (input terminal function selection). (Refer to page 150.)
Pr. 450
"second applied
motor"
Pr. 9
"electronic
thermal O/L
relay"
Pr. 452
"second
electronic
thermal
O/L relay"
First Motor Electronic
Thermal Relay Function
Second Motor Electronic
Thermal Relay Function
RT = OFF RT = ON RT = OFF RT = ON
9999 0
9999
0
0.01 to 500
9999 Other than 0
9999
0
0.01 to 500
Other than 9999 0
9999
0
0.01 to 500
Other than 9999 Other than 0
9999
0
0.01 to 500