5
Connection of stand-alone option units
WIRING
1
z Model ..... FR-V520-11K to 15K, FR-V540-7.5K to 15K
1) Connect the brake resistor across terminals P and PR.
1.3.2 Connection of the brake unit (FR-BU)
Connect the optional FR-BU brake unit as shown below to improve the braking capability during deceleration.
*1 Connect the inverter terminals (P, N) and brake unit (FR-BU (H)) terminals so that their terminal signals match with each other.
(Incorrect connection will damage the inverter.)
*2 When the power supply is 400V class, install a step-down transformer.
*3 Be sure to remove a jumper across terminal PR-PX when using the FR-BU with the inverter of 5.5K or less.
*4 The wiring distance between the inverter, brake unit (FR-BU) and resistor unit (FR-BR) should be within 5m. If twisted wires
are used, the distance should be within 10m.
CAUTION
If the transistors in the brake unit should become faulty, the resistor can be unusually hot, causing a
fire. Therefore, install a magnetic contactor on the inverter's input side to configure a circuit so that a
current is shut off in case of fault.
Do not remove a jumper across terminal P and P1 except when connecting a DC reactor.
Power supply terminal
block for control circuit
PR
P1
U
V
W
Dedicated brake resistor
(FR-ABR)
R1
S1
NPRST
MC
R
S
T
U
V
W
PR
PX
Motor
IM
Inverter
Remove
jumper.
PR
P
N
HA
HB
HC
THS TH2
TH1
PPR
ON
MC
OFF
MC
P
N
T *2
*3
*1
*4
Power
supply
Brake unit
FR-BU
Resistor unit
FR-BR