Mitsubishi Electronics FR-V520-1.5K to 55K Marine Battery User Manual


 
208
Outline dimension drawings
Dedicated motor outline dimension drawings (flange type)
Dimensions table (Unit: mm)
Note)1. Install the motor on the floor and use it with the shaft horizontal.
For use under the shaft, the protection structure of the cooling fan is IP20.
2.
Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3
.
The size difference of top and bottom of the shaft center height is
.
4
.
The 400V class motor has -H at the end of its type name.
Frame Number 90L
SF-V5RUF(H)
Frame Number 100L, 112M, 132S, 132M
SF-V5RUF(H) , , ,
Frame Number 160M, 160L, 180M, 180L
SF-V5RUF(H) , , ,
Frame Number 200L
SF-V5RUF(H) , ,
SF-V5RU
KF
(kW)
SF-V5RU
KF1
(kW)
SF-V5RU
KF3
(kW)
SF-V5RU
KF4
(kW)
Flange
Number
Frame
No.
Mass
(kg)
Motor Shaft End
Terminal Screw Size
D IE KB KD KL LA LB LC LE LG LL LN LZ LR Q QK S T U W
U,V,W
A,B,(C)
G1,G2
1
FF165
90L 26.5
183.6
198.5 27 220 165 130j6 200 3.5 12 402 4 12 50 50 40 24j6 7 4 8 M6 M4 M4
2 1
FF215
100L 37 207 130 213 27 231 215 180j6 250 4 16 432 4 14.5 60 60 45 28j6 7 4 8 M6 M4 M4
3 2 1
FF215
112M 46 228 141 239 27 242 215 180j6 250 4 16 448 4 14.5 60 60 45 28j6 7 4 8 M6 M4 M4
5 3 2
FF265
132S 65 266 156 256 27 256 265 230j6 300 4 20 484 4 14.5 80 80 63 38k6 8 5 10 M6 M4 M4
7 5 3 1
FF265
132M 70 266 156 294 27 256 265 230j6 300 4 20 522 4 14.5 80 80 63 38k6 8 5 10 M6 M4 M4
11 7 5 2
FF300
160M 110 318 207 318 56 330 300 250j6 350 5 20 625 4 18.5 110 110 90 42k6 8 5 12 M8 M4 M4
15 11 7 3
FF300
160L 125 318 207 362 56 330 300 250j6 350 5 20 669 4 18.5 110 110 90 42k6 8 5 12 M8 M4 M4
18
FF350
180M
160
363 230 378.5 56 352 350 300j6 400 5 20 690 4 18.5 110 110 90 48k6 9 5.5 14 M8 M4 M4
22 15 11 185
18 15 5
FF350
180L 225 363 230 416.5 56 352 350 300j6 400 5 20 728 4 18.5 110 110 90 55m6 10 6 16 M8 M4 M4
30 7
FF400
200L
270
406 255 485 90 346 400 350j6 450 5 22
823.5
8 18.5 140 140 110 60m6 11 7 18 M10 M4 M4
37, 45 22, 30 18, 22 290
1K 2K 3K 5K 7K
LN LZ
KL
KD
LA
A
A
Section BB
U
W
T
S
Earth (ground) terminal (M5)
Mark for earthing (grounding)
Connector (for encoder)
MS3102A20-29P
LL
KB
LR
LG LE
QK
Q
LC
LB
B
B
Section
AA
D
Suction
Direction of
cooling fan wind
Exhaust
Section BB
W
U
T
S
LN LZ
KD
KL
IE
A
A
LA
Connector (for encoder)
MS3102A20-29P
Earth (ground) terminal (M5)
Mark for earthing (grounding)
LL
KB LR
LG LE
QK
Q
LC
LB
Section
AA
B
B
D
Suction
Direction of
cooling fan wind
Exhaust
For motor (U, V, W)
For cooling fan (A, B)
For thermal protector (G1, G2)
A
B
G2G1
U
V
W
Earthing (grounding)
terminal (M4)
11K 15K 18K 22K 30K 37K 45K
Section BB
W
S
T
U
A
A
LN LZ
LA
IE
KL
KD
QK
Q
Connector (for encoder)
MS3102A20-29P
Earth (ground) terminal (M8)
Mark for earthing (grounding)
With guard wires
Section
AA
LC
LB
B
B
LR
KB
LG
LE
LL
D
Suction
Direction of
cooling fan wind
Exhaust
Section BB
W
S
T
U
LR
Q
QK
Connector (for encoder)
MS3102A20-29P
Earth (ground) terminal (M12)
Mark for earthing (grounding)
With guard wires
Section
AA
LC
LB
B
B
KB
LG
LE
LL
D
Suction
Direction of
cooling fan wind
Exhaust
A
A
LN LZ
LA
IE
KL
KD
For motor (U, V, W)
For cooling fan (A, B, C) For thermal protector (G1, G2)
Earthing (grounding)
terminal (M8)
Make sure to earth the earth terminal of the flange section
as well as the earth terminal in the terminal box.
0
-0.5