Mitsubishi Electronics FR-V520-1.5K to 55K Marine Battery User Manual


 
67
Parameter list
PARAMETERS
3
PARAMETERS
Operation
selection
functions
33 Speed jump 2A
0 to 3600r/min,
9999
1r/min 9999 93
34 Speed jump 2B
0 to 3600r/min,
9999
1r/min 9999 93
35 Speed jump 3A
0 to 3600r/min,
9999
1r/min 9999 93
36 Speed jump 3B
0 to 3600r/min,
9999
1r/min 9999 93
Display
function
37 Speed display
0, 1 to 9998 1 0 93
Output terminal
functions
41 Up-to-speed sensitivity
0 to 100% 0.1% 10% 95
42 Speed detection
0 to 3600r/min 1r/min 300r/min 95
43 Speed detection for reverse rotation
0 to 3600r/min,
9999
1r/min 9999 95
Second
functions
44 Second acceleration/deceleration time
0 to 3600s/0 to
360s
0.1s/0.01s 5s 78
45 Second deceleration time
0 to 3600s/0 to
360s, 9999
0.1s/0.01s 9999 78
Output terminal
function
50 Second speed detection
0 to 3600r/min 1r/min 750r/min 95
Display
functions
52 DU/PU main display data selection
0, 5 to 12, 17 to
20, 23, 24,
32 to 35, 38, 100
1097
53 PU level display data selection
0 to 3, 5 to 12,
17, 18
1197
54 DA1 terminal function selection
1 to 3, 5 to 12,
17, 18, 21,
32 to 34, 36
1197
55 Speed monitoring reference
0 to 3600r/min 1r/min 1500r/min 100
56 Current monitoring reference
0 to 500A 0.01A
Inverter rated
current
100
Automatic
restart
57 Restart coasting time
0, 0.1 to 5s, 9999 0.1s 9999 101
58 Restart cushion time
0 to 60s 0.1s 1.0s 101
Additional
function
59 Remote setting function selection
0, 1, 2, 3 1 0 103
Operation
selection
functions
60 Intelligent mode selection
0, 7, 8 1 0 106
65 Retry selection
0 to 5 1 0 109
67 Number of retries at alarm occurrence
0 to 10, 101 to
110
1 0 109
68 Retry waiting time
0 to 10s 0.1s 1s 109
69 Retry count display erasure
0 1 0 109
70 Special regenerative brake duty
0 to 15%/0 to
30%
0.1% 0% 92
71 Applied motor
0, 3 to 8, 10, 13
to 18,20,23,24,
30, 33, 34
130111
72 PWM frequency selection
1 to 6 1 1 112
73 Speed setting signal
0, 4, 10, 14 1 0 113
75
Reset selection/disconnected PU
detection/PU stop selection
0 to 3, 14 to 17 1 14 115
77 Parameter write disable selection
0, 1, 2 1 0 116
78 Reverse rotation prevention selection
0, 1, 2 1 0 117
79 Operation mode selection
0 to 4, 6 to 8 1 0 117
Motor
constants
80 Motor capacity
0.4 to 55kW 0.01kW Inverter capacity 120
81 Number of motor poles
2, 4, 6 1 4 120
82 Motor excitation current (no load current) *
0 to , 9999 9999 123
83 Rated motor voltage
0 to 1000V 0.1V
200V (200V class) /
400V (400V class)
120
84 Rated motor frequency
10 to 200Hz 0.01Hz 60Hz 120
90 Motor constant R1 *
0 to, 9999 9999 123
91 Motor constant R2 *
0 to , 9999 9999 123
92 Motor constant L1 *
0 to , 9999 9999 123
93 Motor constant L2 *
0 to , 9999 9999 123
94 Motor constant X *
0 to , 9999 9999 123
95 Online auto tuning selection
0, 1, 2 1 0 126
96 Auto tuning setting/status
0, 1, 101 1 0 120
Third functions
110 Third acceleration/deceleration time
0 to 3600/0 to
360s
0.1s/0.01s 5s 78
111 Third deceleration time
0 to 3600/0 to
360s, 9999
0.1s/0.01s 9999 78
Function
Parameter
No.
Name Setting Range
Minimum
Setting
Increments
Factory Setting
Refer
To
Custo
mer
Setting