PARAMETERS
3
3.5.4 S-pattern acceleration/deceleration curve (Pr. 29, Pr. 140 to Pr. 143, Pr. 380 to
Pr. 383 )
When you have changed the preset speed during start, acceleration, deceleration, stop, or operation, you can
change the running speed by acceleration/deceleration to make adjustment to reach the preset speed. Set
the acceleration/deceleration pattern in Pr. 29 "acceleration/deceleration pattern".
Parameter Name
Factory
Setting
Setting Range Remarks
29
Acceleration/
deceleration pattern
0
0 Linear acceleration/deceleration
Extended mode
1 S-pattern acceleration/deceleration A
2 S-pattern acceleration/deceleration B
3
Backlash measures acceleration/
deceleration
4 S-pattern acceleration/deceleration C
140
Backlash acceleration
stopping speed
30r/min 0 to 3600r/min
Accessible when Pr. 29 = 3
141
Backlash acceleration
stopping time
0.5s 0 to 360s
142
Backlash deceleration
stopping speed
30r/min 0 to 3600r/min
143
Backlash deceleration
stopping time
0.5s 0 to 360s
380 Acceleration S pattern 1 0% 0 to 50%
Accessible when Pr. 29 = 4
381 Deceleration S pattern 1 0% 0 to 50%
382 Acceleration S pattern 2 0% 0 to 50%
383 Deceleration S pattern 2 0% 0 to 50%
speed torque