Mitsubishi Electronics FR-V520-1.5K to 55K Marine Battery User Manual


 
215
Parameter Instruction Code List
Stop selection
function
250 Stop selection 3A BA 2
Operation selection
function
251 Output phase failure protection selection 3B BB 2
Additional functions
252 Override bias 3C BC 2
253 Override gain 3D BD 2
Power failure stop
functions
261 Power failure stop selection 45 C5 2
262 Subtracted speed at deceleration start 46 C6 2
263 Subtraction starting speed 47 C7 2
264 Power-failure deceleration time 1 48 C8 2
265 Power-failure deceleration time 2 49 C9 2
266 Power-failure deceleration time switchover speed 4A CA 2
Brake sequence
278 Brake opening speed 56 D6 2
279 Brake opening current 57 D7 2
280 Brake opening current detection time 58 D8 2
281 Brake operation time at start 59 D9 2
282 Brake operation speed 5A DA 2
283 Brake operation time at stop 5B DB 2
284 Deceleration detection function selection 5C DC 2
285 Overspeed detection speed 5D DD 2
Droop
286 Droop gain 5E DE 2
287 Droop filter time constant 5F DF 2
288 Droop function activation selection 60 E0 2
Digital input
300 BCD input bias 00 80 3
301 BCD input gain 01 81 3
302 Binary input bias 02 82 3
303 Binary input gain 03 83 3
304
Digital input and analog compensation input enable/
disable selection
04 84 3
305 Read timing operation selection 05 85 3
Analog output
306 Analog output signal selection 06 86 3
307 Setting for zero analog output 07 87 3
308 Setting for maximum analog output 08 88 3
309 Analog output signal voltage/current switchover 09 89 3
310 Analog meter voltage output selection 0A 8A 3
311 Setting for zero analog meter voltage output 0B 8B 3
312 Setting for maximum analog meter voltage output 0C 8C 3
Digital output
313 Y0 output selection 0D 8D 3
314 Y1 output selection 0E 8E 3
315 Y2 output selection 0F 8F 3
316 Y3 output selection 10 90 3
317 Y4 output selection 11 91 3
318 Y5 output selection 12 92 3
319 Y6 output selection 13 93 3
Relay output
320 RA1 output selection 14 94 3
321 RA2 output selection 15 95 3
322 RA3 output selection 16 96 3
Digital input 329 Digital input unit selection 1D 9D 3
Relay output 330 RA0 output selection 1E 9E 3
Communication
331 Communication station number 1F 9F 3
332 Communication speed 20 A0 3
333 Stop bit length 21 A1 3
334 Parity check presence/absence 22 A2 3
335 Number of communication retries 23 A3 3
336 Communication check time interval 24 A4 3
337 Waiting time setting 25 A5 3
338 Operation command source 26 A6 3
339 Speed command source 27 A7 3
340 Link startup mode selection 28 A8 3
341 CR/LF presence/absence selection 29 A9 3
342
E
2
PROM write selection
2A AA 3
345 DeviceNet address (lower) 2D AD 3
346 DeviceNet baud rate (lower) 2E AE 3
347 DeviceNet address (higher) 2F AF 3
348 DeviceNet baud rate (higher) 30 B0 3
Function
Parameter
No.
Name
Instruction Code
Link Parameter Expansion Setting
(Instruction code 7F/FF)
Read Write