Mitsubishi Electronics FR-V520-1.5K to 55K Marine Battery User Manual


 
73
At-a-glance guide to functions
PARAMETERS
3
3.2 At-a-glance guide to functions
{....Usable function, × ..... Unusable function
Category
Vector with encoder
Speed Torque Position
SF-V5RU
"Motor with encoder (standard,
constant torque)"
*: This function can be usable under
position control by parameter
setting.
Pr. number Terminal
Control
Speed limit
Pr. 807 to Pr. 809, Pr. 873, Pr. 902,
Pr. 903, Pr. 917, Pr. 918
Terminal 2 (1),
multi-speed
× {
×
Torque limit
Pr. 22, Pr. 803, Pr. 810 to Pr. 817,
Pr. 904, Pr. 905, Pr. 919, Pr. 920
Terminal 3 (1)
{ × {
Offline auto tuning
Pr. 9, Pr. 71, Pr. 80 to Pr. 84,
Pr. 90 to Pr. 94, Pr. 96, Pr. 859
{{
×
Online auto tuning (start time) Pr. 95 = 1 Pr. 95 {{
×
Online auto tuning
(adaptive magnetic flux observer) Pr. 95 = 2
Pr. 95
{{{
Easy gain tuning Pr. 818, Pr. 819 {
×
{
Gain adjustment Pr. 820 to Pr. 827, Pr. 830 to Pr. 837 {{{
Machine analyzer (notch filter) Pr. 862, Pr. 863 {
×
{
0 speed control Pr. 802 {
×
{
Servo lock Pr. 802 {
×
{
Variable excitation Pr. 854 {{{
Speed feed-forward, model adaptive speed control
Pr. 877 to Pr. 881, Pr. 820,
Pr. 821, Pr. 828
{
×
{
P/PI switchover Pr. 180 to Pr. 183, Pr. 187 X44 signal {{{
Speed feedback filter Pr. 823, Pr. 833 {{{
Basic functions
Extended function display Pr. 160 {{{
Maximum speed Pr. 1 {{{
Minimum speed Pr. 2 {{
×
Acceleration time
Pr. 7, Pr. 8, Pr. 20, Pr. 21,
Pr. 44, Pr. 45, Pr. 110, Pr. 111
{{
×*
Acceleration/deceleration pattern
Pr. 29, Pr. 140 to Pr. 143,
Pr. 380 to Pr. 383
{{
×
Jog operation mode Pr. 15, Pr. 16 {{
×
PWM frequency selection Pr. 72, Pr. 240 {{{
Operation mode (PU/external/combined) Pr. 79 {{
×
Switchover mode Pr. 79 {{
×
PU operation interlock mode Pr. 79, Pr. 180 to Pr. 183, Pr. 187 X12 {{{
Operation mode external signal switchover mode Pr. 79, Pr. 180 to Pr. 183, Pr. 187 X16 {{{
Start command (2-wire, 3-wire) Pr. 180 to Pr. 183, Pr. 187 STOP {{{
Parameter write disable selection Pr. 77 {{{
Application functions
Starting speed Pr. 13 {{
×
DC injection brake Pr. 10, Pr. 11, Pr. 12 {{
×
Second, third functions Pr. 180 to Pr. 183, Pr. 187 RT, X9 {{{
Multi-speed setting
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27, Pr. 28,
Pr. 232 to Pr. 239
{{
×*
Remote setting Pr. 59
{{
×
Speed jump Pr. 31 to Pr. 36 {{
×
PID control
Pr. 128 to Pr. 134, Pr. 180 to Pr. 183,
Pr. 187
X14 {
××
Stop selection Pr. 250 {{
×
Power failure stop Pr. 261 to Pr. 266 {{
×
PU stop Pr. 75 {{{
Reset selection Pr. 75 {{{
Forward/reverse rotation prevention Pr. 78 {{{
Automatic restart after instantaneous power failure Pr. 57, Pr. 58 {{
×
Cooling fan on/off control Pr. 244 {{{
Retry function Pr. 65, Pr. 67 to Pr. 69 {{
×
Inverter RS485 communication Pr. 117 to Pr. 124 {{{
Droop control Pr. 286 to Pr. 288 {
××
Control
Applicable
Motor
Function