Display function (Pr. 867)
PARAMETERS
3
3.35 Display function (Pr. 867)
3.35.1 DA1 output response level adjustment (Pr. 867 )
3.36 Terminal function assignment (Pr. 868)
3.36.1 Terminal 1 function assignment (Pr. 868 )
<Terminal 1 function according to control>
* The function is changed to main speed according to the Pr.73 setting with which override, polarity reversible
function, etc. can be selected. (Refer to page 113.)
You can adjust the response level of the output voltage of the output signal DA1.
Parameter Name Factory Setting Setting Range Remarks
867 DA1 output filter 0.05s 0 to 5s Extended mode
The terminal 1 can be multi-functioned.
Parameter Name Factory Setting Setting Range Remarks
868
Terminal 1 function
assignment
0 0, 1, 2, 5, 9999 Extended mode
Pr. 868
Setting
Terminal 1
Function under
Speed Control
Terminal 1 Function
under Torque Control
Terminal 1
Function under
Position Control
Bias/Gain Setting Remarks
0
(factory
setting)
Speed setting
auxiliary
*
Speed limit auxiliary No function
Pr. 902 "speed setting
terminal 2 bias"
Pr. 903 "speed setting
terminal 2 gain"
1
Magnetic flux
command
Magnetic flux command
Magnetic flux
command
Pr. 919 "terminal 1 bias
(torque/magnetic flux)"
Pr. 920 "terminal 1 gain
(torque/magnetic flux)"
2
Regenerative
torque limit
No function
Regenerative
torque limit
Pr. 919 "terminal 1 bias
(torque/magnetic flux)"
Pr. 920 "terminal 1 gain
(torque/magnetic flux)"
Setting can be
made when
Pr. 810 = 1.
5 No function
Forward/reverse rotation
speed limit
(analog polarity
switchover speed limit)
No function
Pr. 917 "terminal 1 bias
(speed)"
Pr. 918 "terminal 1 gain
(speed)"
9999 No function No function No function No function No function
REMARKS
Refer to page 190 for bias/gain settings.
speed torque position